background image

15

Configuring your system

Fine tune the operation of the control panel to your requirements; advanced
programming for PIRs and door/window contacts.

General settings menu

User PIN code

There are 4 user PIN codes that can be

activated and programmed for use.

1

Use the arrow keys to select the PIN number
for changing.

• Only user 1 is activated with a 0000 factory

default code and the code is displayed with a
(0) indicating it is in use.

• The code can be enabled/disabled by pressing

the 

c

key.

2

Press OK when the desired code is selected
and enter a 4-digit number when Enter New
Code is shown. 

3

Press OK to confirm and the display will return
to the previous screen where the new code will
be shown.

• User 1 and User 2 are normal user codes used

to regularly arm and disarm the system. 

• The Cleaner code can only be used to Away

Arm the system. 

• The Temporary code will only disarm the

system once and when Away Arming the
system will automatically erase the code,
perfect for trades people who need access to
your house occasionally.

• Ensure that user1, user 2, cleaner and

temporary codes are all different.

Master PIN code

Programs the PIN code used for accessing the

programming mode.

1

The system asks you for a new PIN number.

Enter a new 4-digit code and press OK.

2

Confirm by keying in your PIN number again.

3

Press OK, if an incorrect code is entered, a
message prompts the previous step.

• The master PIN code is used to protect the

programming mode from unauthorised use.

• The user code and the master code can be

made the same for easier use, however it is
recommended that they are made different
where one responsible person has
programming access only.

Entry time

Enables you to alter the entry delay time.

Options are 0 sec, 10 sec up to 70 sec in 10-
second increments.

1

Use the arrow keys to switch between options.

2

Press OK to confirm.

• 10 seconds is set as factory default.

Exit time

Enables you to alter the exit delay time.

Options are 0 sec, 10 sec up to 70 sec in 10-
second increments.

1

Use the arrow keys to switch between options.

2

Press OK to confirm.

• 10 seconds is set as factory default.

Alarm length 

This is for selection of the period of time that

the control unit will sound or not when the alarm
is activated.

1

Press the arrow keys to select the option.

2

Press OK to confirm.

• Siren On is the factory default.
• It is recommended that the siren is left on.

Exit sound 

Turns on and off the exit delay audible warning.

1

Press the arrow keys to select the option.

2

Press OK to confirm.

• Exit Sound Low is set as factory default.
• The exit sound can be selected for high or low

volume.

Exit sound 

Turns on and off the entry delay audible

warning.

1

Press the arrow keys to select the option.

2

Press OK to confirm.

• Entry Sound Low is set as factory default.

The exit sound can be selected for high or low

volume.

Door chime

Turns on and off the door chime in the control

unit when an entry sensor is activated.

1

Press the arrow keys to select the option.

2

Press OK to confirm

• Door Chime Off is set as factory default.
• The door chime can be set for high or low

volume.

Interference

Sets the interference display

• Radio interference is unlikely, but can effect the

operation of the system. The siren (see Further
siren programming) and the control unit have
the ability to detect interference and give
warnings.

1

Use the arrow keys to choose the setting.

2

Press OK to confirm the setting.

• I.Disp Off is set as factory default.
• When the interference detection is switched off

the unit will not respond at all to interference.

• When the interference detection is switched

Содержание HSA3600

Страница 1: ...HSA3600 Control panel alarm system Installation Programming Operating Keep in a handy place for reference and for future maintenance Helpline 01902 635998 ...

Страница 2: ...r when a battery change is required Home and away arming In addition to fully arming the system the HSA3600 also allows you to home arm The home mode allows you to arm the system in such a way that you can protect the non sleeping areas such as downstairs allowing access from the bedroom to the bathroom for example without triggering the alarm Take care of your safety Display extreme caution when ...

Страница 3: ...ton contents Control unit External siren 2 x PIRs 2 x door contacts 2 x door contact magnets 4 x 1 5V AAA alkaline cells 6 x 1 5V AA alkaline cells 8 x 1 5V D alkaline cells 2 x large adhesive pads 2 x small adhesive pads 4 x small wall plugs 12 x medium wall plugs 4 x large wall plugs 4 x 4mm x 30mm cross head fixing screws 4 x 3 5mm x 22mm cross head fixing screws 12 x 3 5mm x 16mm cross head fi...

Страница 4: ...ot be mounted on or near large metal objects Avoid obvious sources of electrical interference such as fridges and microwave ovens Tamper switches When mounting devices ensure that any tamper switches close fully On uneven surfaces it may be necessary to place packing behind the switch for reliable operation Extend the system Extend the system in the future to increase your security or as your need...

Страница 5: ...ires or boilers and do not position directly above radiators Avoid mounting the PIR directly facing a window Do not point the PIR at a door protected by a door window contact Keyfob remote control accessory Can be used inside or outside the property and can be kept on your keyring Door Window contact Select a door that will be the main point of entry and exit usually your front door Mount as high ...

Страница 6: ...h the four screws taking care not to over tighten WARNING The siren is very loud avoid touching the tamper switch arm or opening and closing the lid unnecessarily 6 OK 5jkl 6mno 7pqrs 8tuv 9wxyz 0 1 2abc 3def 4ghi Unpack all the parts onto a table top Identify all the parts to get to know the system and get up and running quickly by programming them on a table top before installing them 2 Siren WA...

Страница 7: ...PP3 battery as shown The Tx LED will flash briefly while components initialise Smoke detector accessory Twist off backing plate and insert 4 AAA batteries as shown Remote keyfob accessory Slide off the battery cover insert the 23A MN21 battery as shown and replace cover Switch to on Tamper switch Jumper switch Learn Test button Tamper switch Jumper switch Extension terminals Magnet Learn Test butt...

Страница 8: ...efore you can deactivate the alarm or enter any information you must enter PIN code This is factory set to 0000 Disarm 1 Key in 0 if not already lit the display will light up and Enter Code is displayed 2 Key in 000 to complete the factory set code 3 Press OK you will hear 2 short beeps and the display will show Alarm Off The system is now disarmed If no code is entered for a while the display wil...

Страница 9: ...ke care not to activate the siren tamper switch unnecessarily The siren is programmed by the jumper switches in the left hand compartment 1 Lift off jumper 1 and park it The siren will beep and flash The siren is now in learn mode 2 Lift off jumper 5 and park it This must be left in the off position permanently If jumper 3 and jumper 4 are removed during the learning in process the siren will only...

Страница 10: ...sting Ensure they are replaced in your chosen positions before replacing the covers 7 Replace the battery and compartment covers ensuring that the gasket between the electronics compartment and cover is correctly located and the wires placed in their slots to ensure a good seal from the environment 8 Enable the tamper switch by selecting Program Siren menu on the control unit then Siren A T On and...

Страница 11: ... or flaky paint or on a rough surface Screw mounting Remove the front of the device and if necessary break through the appropriate knockout where the plastic is thinner Using the holes as a template drill holes in the surface and insert the wall plugs if fixing into the plaster or brick Control unit Open the control unit and using the 4 holes as shown fix the control unit to a wall as described un...

Страница 12: ...n condition is detected 4 Remove the detector put the jumper in the normal off position Screw the detector back onto its base When the jumper is in the normal off position the indicator light will normally be off It will only light if there is a problem either a low battery or a tamper condition Ensure that the jumper is in the normal off position when testing is finished otherwise low battery and...

Страница 13: ...tivate the alarm immediately while if a Home Omit sensor is triggered the control unit will not respond if in home mode If a 24 hour alarm fire alarm personal attack alarm tamper or auxiliary alarm is triggered the control unit will activate the alarm immediately irrespective of what alarm mode the control unit is in During an alarm the control unit will sound the siren depending on the programmed...

Страница 14: ...led up and down and viewed with the keys the most recent event will be at the start Dual key alarm feature Personal emergency alarm A personal emergency alarm can be triggered at the control unit by pressing keys 1 and 3 simultaneously for 2 seconds Fire alarm A fire alarm can be triggered in a similar way by pressing keys 4 and 6 simultaneously for 2 seconds System records For your future conveni...

Страница 15: ... alter the entry delay time Options are 0 sec 10 sec up to 70 sec in 10 second increments 1 Use the arrow keys to switch between options 2 Press OK to confirm 10 seconds is set as factory default Exit time Enables you to alter the exit delay time Options are 0 sec 10 sec up to 70 sec in 10 second increments 1 Use the arrow keys to switch between options 2 Press OK to confirm 10 seconds is set as f...

Страница 16: ...em or by editing them afterwards the procedure is similar for both situations 1 When the Enter zone NAME menu is selected while in the Device menu the keypad can be used to enter text similar to texting with a mobile telephone The keys have the following functions 1 1 2 ABCabc2 3 DEFdef 3 4 GHIghi4 5 JKLjkl5 6 MNOmno6 7 PQRSpqrs7 8 TUVtuv8 9 WXYZwxyz9 0 space 0 b c Upper or lower case selection Fo...

Страница 17: ...n The light does not flash normally when it is sensing movement unless the jumper is in the On test position If the LED flashes it indicates that it has either been tampered with or the battery is getting low and needs replacing Further door contact programming The door contact can be set to work in 6 different modes Whether it is armed when the control unit is in home or away armed condition Whet...

Страница 18: ...help button and a smoke alarm These are available separately from your local stockist Testing the system Testing the system should be done on a regular basis and after any alterations PIR sleep feature The PIR has a built in sleep timer to save battery power If there is no movement in front of the PIR for 1 minute the PIR will become ready to signal and any movement will be reported The PIR will s...

Страница 19: ... complete Using To activate press and hold the red button for at least 2 seconds LED will light momentarily and the alarm will be activated To silence an alarm press and hold down the red button after 10 seconds the LED will light momentarily for a second time alarm will be silenced Please note that silencing the alarm with the help button does not reset the system If the alarm is armed prior to a...

Страница 20: ...ere all the zones with the sensor types and names are listed 1 Use the arrow keys to move the cursor to the position where the device listed is to be deleted The list is displayed in zone number order 2 Press OK The selected device will be displayed to confirm Press a to exit if you do not want to delete this device the screen will return to the previous list 3 Press OK to delete Editing a device ...

Страница 21: ...b The LED will either be very dim or will not light at all when the battery is low Change the battery as soon as possible with an alkaline replacement Keypad The Tx will flash repeatedly every time the device is used indicating a low battery and the control unit will identify the keypad with a low battery Before changing the battery check that the tamper switch is operating correctly 1 Disable tam...

Страница 22: ...th flying near the PIR can trigger an alarm PIR LED flashes when the jumper is in the normal position Batteries are low or the tamper switch is disturbed Check that the tamper spring is making contact with the base If the tamper switch is OK change batteries with new alkaline replacements PIR does not respond to movement when jumper is in test position Batteries are completely exhausted Change bat...

Страница 23: ...ontrolled dual edge sequential pulse count with pulse length discrimination Radio 433 92Mhz AM transmitter Power supply 4 5V 3 X AA alkaline cells 3 years minimum typical domestic service life Door contact Radio Microprocessor controlled 433 92Mhz AM transmitter Power supply 3V 2 X AAA alkaline cells 3 years minimum typical domestic service life 50 activations per day Smoke detector Detector Micro...

Страница 24: ...ds WV13 1LA Yale is a registered trademark E2 11 03 Key points Stopping the alarm Key in your PIN code and press OK on the control panel If any of the devices beep or flash they have either been tampered with See trouble shooting page 22 or require a new battery See how to change a battery page 20 ...