Mounting alarm devices
4
WARNING
To prevent the alarm from activating during installation, the siren must have its
tamper disabled and the control unit must be in ‘Walk Test’/Programme mode.
Control Unit Mounting
Table top
Remove the mounting back plate (if fitted) and
simply place on top of a table on its rubber feet.
•
If the mounting plate has been fitted with the
power on, the control unit will show a unit tamper
condition when the plate is removed. To cancel
make sure that the mounting plate is not fitted
and power down by removing the power plug and
switching off the battery. Reconnect power and
switch the battery back on. The unit tamper will be
reset and not activate again unless the plate is put
back on.
Wall Mounting
Using the two holes on the mounting back plate,
mark the position of the holes. Drill two holes and
fix with the screws and plugs provided. Hook the
control panel onto the plate. Ensure that the control
unit is fitted at approximately chest height where
the display can be easily seen and the keypad
convenient to operate.
•
The control unit tamper protection will
automatically arm when mounted on the back
plate.
Disabling the system tamper
Before mounting it is important to disable the
Siren and system tamper to avoid the siren
sounding an alarm.
1
Press the
pr
key and enter a user PIN code
followed by
✓
.
2
The control unit is now in programming mode,
Select D/-, then Program Siren and
Siren Tamp. Off using the
pq
✓
keys.
3
Press
✓
when in the Siren Tamp. Off menu
and the control unit will beep followed by an
acknowledgement pip from the siren.
• Siren programming is described more fully
in “Control Panel Menu System in Detail” in
section 5.
• The siren tamper will now be disabled for 1
hour after which it will automatically arm again.
If longer is needed to fit the siren then simply
repeat the steps above.
•
Leave the control unit in programming
mode to stop the system responding to
tampers. If the control unit automatically
times out, re-enter programming mode
again.
Mounting the siren
Ensure the tamper switch is fully depressed when
the siren is mounted. If there is a gap, pack with a
suitable spacing material.
Round
Siren
Base
Wall
Spring Guide
Spring compressed
firmly against wall
Square Siren Base
Plunger must
be pressed in
fully against
wall
Wall
1
Find a location where the siren is to be mounted.
2
Using the large screws and wall plugs provided,
screw the siren onto the wall through the 4
mounting holes on the siren base.
3
Fix the siren cover with the securing screw.
4
Using the Programming D/- menu enable
the siren tamper (see the end of this section “Final
step:”) and Arm and Disarm the system with the
control unit.
5
If there are 5 short beeps when armed, the tamper
switch is NOT fully depressed and will need to be
adjusted.
Unset the system and disable the siren tamper as
described above before adjusting the siren tamper
switch. If there is a gap between the wall and the
tamper switch mechanism, pack with a suitable
spacing material.
When adjusted repeat the steps above from steps
3 through 5.
6
If there is one short beep and flash when armed,
the siren is mounted correctly and the siren
installation is complete.