Operation
LED indicator
Off
Normal operation
LED flash
(2 sec)
- Detects motion during Low
battery, Tamper activated or Test
mode.
- Tilt tamper switch is activated.
Tilt Switches
When the Door contact is tilted, a Tamper alarm
will be triggered. The Tilt Switch is disabled by
factory default. Opening the unit will also trigger
tamper alarm via the tamper spring
Enable
Secure the door contact onto a wall or
bracket, so that the Tamper Switch is
pressed. Press & hold the Test button
for 8 sec. The LED will flash for 5 times,
indicating Tilt Switch enabled.
Disable
Take out the battery and reinsert it to
disable the Tilt tamper mechanism. See
“Changing batteries” below.
Test Mode
Press Test button once to enter test mode. Under
test mode, the LED lights up whenever movement
is detected. The device will auto exit test mode
after 3 minutes.
Changing Batteries
The 1x 1/2 AA size lithium battery has a battery
life of approximately 2 and a half years (based
on 20 activations per day). When the low battery
condition is shown, the device should have
enough power to operate for one month.
Step 1: Login to the engineer menu on the
control panel.
Step 2: Dismount the DC and remove the
batteries. Press Test button for ten times.
Step 3: Insert new 1/2 AA lithium battery.
Step 4: Replace the cover and mount the sensor.
Step 5: Press & hold the test button for 8 sec to
enable the Tilt Switch.
Step 6: Exit the engineer menu and return to
standby on the control panel.
Specification
Environmental conditions:
-10c to 40c , relative humidity 85% non-
condensing. Indoor use only
Radio
868.35MHz FM
Battery:
1x 3.6V 1/2AA Lithium battery
Dimension:
107mm x 32mm x 22mm (main unit)
45mm x 14mm x 11mm (magnet)
Standard :
EN300-220-1
EN301489-1,3
EN60950
PD6662:2010 Grade 2 Class 2