Yale EF-IPBox Скачать руководство пользователя страница 1

Easy Fit SmartPhone alarm 

system (EF-IPBox) 

V3 onward 

Installation · Programming · Operating

Keep this manual safe for reference and future maintenance

Introduction

Contents

Thank you for choosing the Yale Wireless Alarm System. 
This simple to install system has been designed with the 
user in mind. 

All the components are self contained and no connections 
are needed between the units. There is no need to 
damage the home decor, lift carpets or run cables. 

You can install up to 

20

 devices (Max. 6 PIR Cameras) in 

this system. As well as extra door/window contacts, PIRs 
and smoke detectors, you can add keyfob remote controls 
and keypads for added control convenience.

 
There is no need to wire into the mains supply or seek 
the services of a qualified electrician. The control box is 
powered by an adaptor and all other components are 
powered by battery (all batteries included).
Batteries will operate for 2 years or more before they need 
changing. Regular testing and battery changes (when 
notified by the system) will ensure reliability and peace of 
mind. 

The security detectors and external siren are ‘tamper’ 
protected. Any unauthorised tampering with these items 
when the system is armed will result in an alarm.

Display extreme caution when using ladders or steps, 
please follow manufacturer’s instructions.
Be careful when using hand and power tools and follow 
the manufacturer’s guidelines when using them. Take care 
that the correct tools are used. Wear goggles or protective 
clothing where required.
The external Siren is extremely loud, please ensure you 
replace the cover and retreat to a safe distance before 
testing.

The dialling facilities must only be used with persons who 
have consented to being contacted by the system.
The system is not to be used to make 999 emergency 
calls directly. Yale do not hold responsibility for any actions 
taken by emergency services for incorrect use of the 
dialling facility.

Special Notes on Compatibility:

This alarm system is NOT compatible with SmartHome 
Alarm, HSA6000 series and HSA3000 series accessories. 
Please note the prefix “

EF-

” on the front of the part 

number to indicate compatibility. It is also compatible with 
accessories labelled “For use with SmartPhone alarm 
only”.

Information and illustrations are subject to change within this 
document. Yale reserves the right to alter the specification and 
product design at anytime without notice. Yale® is a registered 
trademark. © 2014 ASSA ABLOY. All rights reserved. 

1  Location planning 

2

2  Unpack all the parts 

4

3  Initial set-up 

6

4  Mounting Devices 

8

5  Using the System 

11

 

Adding and using Accessories 

13

 

Changing the batteries 

15

 Troubleshooting 

17

 Specifications 

18

Recommended Installation Sequence

We recommend you follow the simple install 
sequence, headings numbered 

1-5

Содержание EF-IPBox

Страница 1: ...r s instructions Be careful when using hand and power tools and follow the manufacturer s guidelines when using them Take care that the correct tools are used Wear goggles or protective clothing where required The external Siren is extremely loud please ensure you replace the cover and retreat to a safe distance before testing The dialling facilities must only be used with persons who have consent...

Страница 2: ...ystem in the future to increase your security or as your needs change For example add extra PIR detectors and extra door window contacts Choosing Location To minimise interference avoid locating devices close to metal framework glass electrical appliances especially wireless devices and electric cables Please note that the presence of high density material metal glass etc in the transmission path ...

Страница 3: ...t aim a PIR at this door or window PIR Movement Detector or PIR Camera Mount in a position such that an intruder would normally move across the PIRs field of view Height should be between 1 9 and 2 metres above floor level Location in a corner will ensure wider room coverage Do not mount the PIR where its field of view will be obstructed e g by curtains ornaments etc Do not point directly at sourc...

Страница 4: ...e care not to activate the siren tamper switch unnecessarily 1 Remove the cover by unscrewing the single screw located on the lid Power switch to ON position PIR Movement Detectors EF PIR 1 Pull out the plastic pull tab on the back of the PIR This will activate the batteries Door Window Contacts EF DC 1 Pull out the battery saver tab on the side to activate the battery Learn Power Battery On Off B...

Страница 5: ...ob remote control accessory Slide off the battery cover insert the 23A MN21 battery as shown and replace battery cover Switch to on Help button accessory Remove the cover by loosening the fixing screw and insert the 12V battery supplied as shown Please ensure you observe battery polarity Tamper switch Jumper switch Tamper switch Jumper switch Magnet Extension terminals Learn Test button Learn Test...

Страница 6: ...hown Once you have received BOTH the authentication email and SMS click on the email link i Select New user click here i Enter your details Panel MAC can be found on the Control box s sticker Close app Wait for 1 Authentication email also check spam folder 2 SMS with Auth code i Enter SMS Auth code i i If you encounter errors it is due to the control box not communicating with our server Please ch...

Страница 7: ...utton Press 8 and 9 together Learn button Learn button ale Y Learn Button Press hold for 3 seconds One by one press the learn button on the accessories The control box will beep every time a new device is registered Exit Learn Mode Press and hold the control box learn button for at least 3 seconds The LED should now stop flashing Proceed to installation For the following accessories please hold th...

Страница 8: ... will show up on the last screen see above The radio signal strength is shown by a number under the device name This number ranges from 1 to 9 strongest Where possible please ensure devices show 3 or above for optimal performance When you are happy that all your devices can communicate with the box please proceed to mounting the accessories Mounting the siren Ensure the tamper switch is fully depr...

Страница 9: ...that some surface or environment i e exposure to Sunlight may be unsuitable for this mounting method Please use screw mounting in these cases Mounting using screws and wall plugs Loosen the bottom screw and open the door window contact Knock out the holes on the base as shown Drill holes into the mounting surface using the holes in the knockouts on the base as template Fit wall plugs if required a...

Страница 10: ...e alarm is triggered the system will send an email push notification iOS only and SMS to alert the owner The network traffic condition will determine how quickly the user is alerted There may be noticeable delay should the third party email SMS gateway become congested You will be prompted on the app when trying to arm with your door window open i It is possible to arm the system with open door co...

Страница 11: ...he system However the person inside the house can move freely around without triggering the alarm Home mode is usually used to protect the ground floor when you are upstairs in bed To enable home arm you need to choose the sensors to be ignored during this mode It would typically be the bedroom PIR etc if you want to arm your system during the night These sensors should be set to Home Omit in orde...

Страница 12: ...videos can be kept in the Yale Server the oldest images videos are automatically deleted to make space Users are advised to delete unwanted images videos Adding alert email SMS You can add delete email and SMS phone numbers for alert during alarm condition Only Burglar events will be reported via SMS while you can choose to have ALL events or Burglar only reported via email Hint our report email w...

Страница 13: ...o known as slave mode 4 Quit test mode by pressing the disarm key twice The keypad code and mode setting has been completed The keypad will now use the same pincode that is set for the control panel unit Forgotten keypad code different to disarming pincode If the keypad code is accidentally forgotten the keypad can be reset to factory default 0000 using the following steps 1 Unscrew the two keypad...

Страница 14: ... fire alarm with a radio fire alarm signal to the control unit Testing Smoke detector testing should be done on a regular monthly basis Pressing the test button will make the LED flash the audible sounder chime and will send a radio test signal to the control unit when the button is released If nothing happens after pressing the test button it indicates the batteries will need changing Recalibrati...

Страница 15: ... because any other battery can cause problems with the operation of the system Typical life of batteries is two years or more Ensure the correct steps are taken when changing batteries in tamper protected devices PIR PIR Camera Battery Change When the battery is low the LED will flash when any movement is detected The batteries are changed as follows 1 Ensure the system is disarmed 2 Loosen the ca...

Страница 16: ... number key and check that the LED lights If the LED lights the new battery installation is successful screw keypad back on and the battery change is complete Help Button Battery Change When the battery is low the LED will glow dimly when the button is pressed The battery is changed as follows 1 Loosen the bottom case screw and take button cover off base 2 Insert new CR2032 coin cell with the side...

Страница 17: ...false alarms Check pets have no access to protected area Check that PIR is not pointed at sources of heat or moving objects e g fluttering curtains Check that PIR is not mounted above convector heaters or pointing directly at windows PIR LED flashes Batteries are low or the tamper switch is disturbed Check that the tamper switch spring is making contact with base If the tamper switch is OK change ...

Страница 18: ...dual edge sequential pulse count with pulse length discrimination Radio 868MHz FM Power supply 4 5V 3 x AAA alkaline cells 2 years typical domestic service life without supervision Movement detection range 12m 110 PIR image camera Alarm processing Microprocessor controlled dual edge sequential pulse count with pulse length discrimination Radio 2 4GHz Power supply 2 x AA 1 5V Alkaline cells 2 years...

Страница 19: ...EF PS EF PETPIR Date 15 04 13 On behalf of ASSA ABLOY Ltd ASSA ABLOY Ltd School Street Willenhall West Midlands England WV13 3PW John Ward Director 17 Model HSA3400 HSA3020 HSA3060 HSA3010 HSA3050 HSA3045 HSA3080 HSA3030 HSA3070 EN 300 220 1 V2 3 1 2010 EN 300 220 2 V2 3 1 2010 EN 301 489 1 V1 8 1 2008 EN 301 489 3 V 1 4 1 2002 EN 60 950 1 2006 A11 2009 A1 2010 A12 2011 EF KF EF KP EF BX EF SD EF ...

Страница 20: ...discrimination Radio 433 92MHz AM transmitter Power supply 4 5V 3 x AA alkaline cells 3 years typical domestic service life 1 minute sleep timer Movement detection range 15m 110 Door window contact Radio Microprocessor controlled 433 92MHz AM transmitter Power supply 3V 2 x AAA alkaline cells 3 years typical domestic service life Smoke detector Radio Microprocessor controlled 433 92MHz AM transmit...