Troubleshooting

Unit triggers without cause

There  may  be  interference  from  another 

keyfob or wireless equipment nearby.  Reset 

the  keyfob  ID  code  and  ‘re-learn’  it  into  the 

system (refer to “reset procedure”)

Audible Interference through speaker

Occasionally, other electrical items in a room 

(TVs,  radios  etc)  can  interfere  with  the  main 

unit’s  speaker.    Try  moving  the  unit,  or  the 

suspected  item  affecting  it,  to  a  different 

location.

Poor sound quality on message

Try  re-recording  your  message,  speaking 

clearly into the main unit.

Keyfob low battery indicator

The  light  on  the  keyfob  will  turn  red  instead 

of  green  when  the  ‘Yale’  button  is  pressed.  

Replace battery.

Your nominated contact(s) cannot acknowledge 

the call

The  call  acknowledgement  will  only  work  if 

your nominated contact is using a touch-tone 

(DTMF) phone.

Important notes

To  indicate  low  battery  on  the  main  unit  (when 
running  on  batteries  only)  the  main  unit  red  light 
will be on permanently.  Plug in mains adaptor and 
replace backup batteries.

The system is not waterproof and is only intended 
for indoor, dry usage.

This product is purely a communication device and 
should  not  be  used  as  a  substitute  for  a  specific 
medical or emergency alarm.  If you have any special 
requirements, you should always consult a medical 
professional for appropriate advice on tele-medical 
equipment.

This device should never be used to dial emergency 
telephone numbers (i.e. 999).

Keep the main unit away from direct sunlight or hot 
surfaces. 

Only  use  the  supplied  power  adaptor.    Other 
adaptors may damage the main unit.

Always  inform  your  nominated  contact(s)  prior 
to their inclusion and agree a particular course of 
action upon their receiving your automated call.

Specification

• Frequency: 433.92MHz
• Range: 30 metres free line of sight
• Power supply- 
  Main Unit: 6V DC adaptor or 4 x AAA alkaline  
  batteries (backup power, not included)
  Remote Keyfob: 12V A23S battery

Adaptor information:

Input: 100-240V 50-60Hz 0.2A
Output: 6.0V 1000mA

Consumer helpline

If  you  have  a  question  concerning  your  system 
please call the helpline on:

0871 70 30 630 (UK only)

 –

 

Lines open 8am-5pm, Monday-Friday

Calls cost approximately 10p per minute from a UK landline
From outside the UK please call 

+44 (0)1902 635998

Additional Information

 

Yale

School Street, Willenhall, 

West Midlands WV13 3PW

Tel: +44  (0) 1902 364606

Fax: +44 (0) 1902 364692

email: [email protected]

www.yale.co.uk

E1 04/07

18

Specifications

All devices

EMC

Tested to ETS 300 683
Radio Components tested to EN

300 220-1

Environmental conditions

-10°C to 40°C, relative humidity

70% non-condensing for all units
except the external siren. Siren: -20°C
to 50°C, relative humidity 95% non-
condensing

Radio operational range

30m in a typical domestic

installation, range can vary depending
on building construction, device
positions and RF environment

Housings

ABS/polycarbonate

Siren

Siren output 

104dBA sound pressure @

1m minimum

Radio

433.92MHz AM super heterodyne

receiver with jamming detection 

Po

wer supply 

6V, 4 x D alkaline cells. 3

years typical service life 

P

assive infra red (PIR) detector

Alarm processing 

Microprocessor

controlled dual edge sequential pulse
count with pulse length discrimination

Radio

433.92MHz AM transmitter 

Po

wer supply 

4.5V, 3 x AA alkaline cells.

3 years typical domestic service life, 1-
minute sleep timer 

Movement detection range 

15m, 110°

Door/window contact

Radio

Microprocessor controlled

433.92MHz AM transmitter 

Po

wer supply 

3V, 2 x AAA alkaline cells. 3

years typical domestic service life 

Smoke detector

Radio

Microprocessor controlled

433.92MHz AM transmitter 

Po

wer supply 

6V, 4 x AAA alkaline cells. 3

years typical domestic service life

Keyfob remote control

Radio

Microprocessor controlled

433.92MHz AM transmitter 

Po

wer supply 

12V, 23A/MN21 alkaline

miniature "lighter" battery. 3 years
typical domestic service life 

Keypad remote control

Radio

Microprocessor controlled

433.92MHz AM transmitter 

Po

wer supply 

3 x AAA alkaline cells. 3

years typical domestic service life

Help button

EMC

Tested to EN 300 220-1 and ETS

300 683

Environmental conditions 

-10°C to

40°C, relative humidity 70% non-
condensing

Radio operational range 

30m in a

typical domestic installation. Can vary
depending on building construction and
RF environment

Radio

Microprocessor controlled

433.92MHz AM transmitter

Power supply 

12V 23A/MN21 alkaline

miniature ‘lighter battery’. 3 years
typical domestic service life

0560

WEEE

Note: Waste electrical products should 
not be disposed of with household 
waste. Please recycle where facilities 
exist. Check with your local authority or 
retailer for recycling advice.

Содержание Distress alert system

Страница 1: ...tress alert system Alerts friends and family at the press of a button Allows independence while keeping you in touch Helps you maintain your active lifestyle User Manual Keep this manual safe for future reference ...

Страница 2: ...n on main unit and keyfob to Input phone numbers including area codes Set maximum 3 phone numbers Record voice message Rear view 4X AAA A A Alkaline cell Optional backup batteries AAA 1 5V Landline phone Optional Landline socket Mains Initialisation Turn on the main unit and wait until the main unit s red LED light turn off 75 Seconds Proceed to next step To set up other numbers use same sequence ...

Страница 3: ...g further keyfobs for learning in If the red light goes out the main unit is no longer in learn mode In order to return to learn mode turn the main unit OFF and then back ON again Wait for the static red light and continue your learning process Setting contact telephone numbers After the red light goes out you can program up to 3 telephone numbers landline or mobile First press the handset and sta...

Страница 4: ...n will last for 50 seconds before 3 warning beeps indicate that the call will end within 10 seconds To extend the call for a further 60 seconds your nominated contact should press any number on their telephone keypad After the call is ended the system is ready to use Testing your system To ensure your system is set up correctly test it fully before using Ensure your nominated contacts are aware th...

Страница 5: ...land WV13 3PW DAS1100 DAS11 Date 20 04 07 On behalf of ASSA ABLOY Ltd ASSA ABLOY Ltd School Street Willenhall West Midlands England WV13 3PW John Ward Director 17 Model HSA3400 HSA3020 HSA3060 HSA3010 HSA3050 HSA3045 HSA3080 HSA3030 HSA3070 EN 60950 1 2001 A11 2004 ETSI EN 301 489 3 V 1 4 1 2002 08 ETSI EN 300 220 3 V 1 1 1 2000 09 TBR 21 ...

Страница 6: ...0 60Hz 0 2A Output 6 0V 1000mA Consumer helpline If you have a question concerning your system please call the helpline on 0871 70 30 630 UK only Lines open 8am 5pm Monday Friday Calls cost approximately 10p per minute from a UK landline From outside the UK please call 44 0 1902 635998 Additional Information Yale School Street Willenhall West Midlands WV13 3PW Tel 44 0 1902 364606 Fax 44 0 1902 36...

Отзывы: