26
4
Wrong Code
Entry Limit
1 byte
0x03
0x0A
0x05
Adjust the limit for wrong
code entries allowed by your
lock
.
61
5
Language*
1 byte
0x01
(English)
0x03
(French)
0x01
(English)
Set the language to English
(1), Spanish (2), or French
(3).
60
7
Shut down
time
1 byte
0x0A (10
seconds)
0x84 (132
seconds)
0x3C (60
seconds)
Adjust the time your lock is
shut down after reaching its
wrong code entry limit.
81
8
Operating
mode
1 byte
0x00
(Normal
Mode)
0x02
(Privacy
Mode)
[0x8002,
0x8004,
0x8109
&
0x810A]
0x00
(Normal
Mode)
Set the Operating Mode to
normal mode(0), vacation
mode(1), privacy mode(2).
[0x8002, 0x8004, 0x8109
& 0x810A]
75
Set the Operating Mode to
normal mode, keypad disable
mode or passage mode.
[0x8104]
76
0x03
(Passage
Mode)
[0x8103
&
0x8104]
Set the Operating Mode to
normal mode, vacation mode,
privacy mode or passage
mode.
[0x8103]
83
Содержание Assure Lock YRC256
Страница 8: ...Changing Handing if necessary continued 3 8 P N YRL EMICL 256 KFTSINSTL FUL Rev A...
Страница 14: ...14 P N YRL EMICL 256 KFTSINSTL FUL Rev A 8 Installing Lock Chassis 10 32 x 1 1 2 PPHMS Inside of Door x2 UP...
Страница 16: ...16 P N YRL EMICL 256 KFTSINSTL FUL Rev A Testing Latchbolt Operation Outside of Door...
Страница 21: ...21 P N YRL EMICL 256 KFTSINSTL FUL Rev A Testing Final Latchbolt Operation Outside of Door Inside of Door...
Страница 34: ...34 P N YRL EMICL 256 KFTSINSTL FUL Rev A Programming Troubleshooting Check or gear Symptom Suggested Action...