32
P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A
Definitions
Previous:
While in Menu Mode, pressing this icon cancels the current operation and returns the user to the previous
step.
Tamper Alert:
Audible alarm sounds if attempting to forcibly remove outside lock from door.
Shutdown Time:
The unit will shutdown (flashing RED) for sixty (60) seconds and not allow operation after the wrong
code entry limit (5 attempts) has been met.
Volume Setting Mode:
The volume setting for PIN code verification is set to
Low (2)
by default; otherwise it can be set
to
High (1)
or
Silent (3)
for quiet areas.
User PIN Code:
The user code operates the lock. The maximum number of user codes with Z-Wave Plus or Zigbee
network module is 250; without network module or with iM1 network module, maximum is 25; with Bluetooth,
maximum is 12. Note: When deleting user pin code(s), screen will display user pin code being deleted.
Wrong Code Entry Limit:
After five (5) unsuccessful attempts at entering a valid PIN code, the unit will shut down and
not allow operation for sixty (60) seconds.
Privacy Mode:
Privacy mode is disabled by default. Enable Privacy mode by pressing the privacy button for 4 seconds
to put lock in do-not-disturb mode (all pin codes are disabled).
Low Battery:
When battery power is low, the Low Battery Warning indicator flashes RED. If battery power is completely
lost, use the 9Volt battery override. To use the 9V battery override apply 9V battery, in either direction, to terminals
below the touchscreen for backup power option. Wake up the lock and enter your pin code to unlock the door.
Master PIN Code:
The Master PIN code is used for programming and for feature settings.
It
must be created prior to
programming the lock.
The Master code will also operate (unlock/lock) the lock.
One Touch Locking:
When the latch is retracted, activating the keypad will extend the latch (during Automatic Re-lock
duration or when Automatic Re-lock is disabled). When One-Touch Re-lock is
not
in use
(disabled),
any valid PIN code
will re-lock the lock.
Automatic Re-lock Time:
After a successful unlock, the unit will re-lock automatically after duration selected in the
Advanced Lock Settings
(Main Menu selection #3).
Language Setting Mode:
Choosing English (1), Spanish (2) or French (3) becomes the (default) setting for the lock's
voice prompts.
Inside Indicator Light:
Located on the interior escutcheon. Shows active status (Locked) of lock and can be enabled or
disabled in the
Advanced Lock Settings
(Main Menu selection #3).
Network Module Setting:
With the optional Network Module installed, this setting becomes available thru the Main
Menu (7) and allows the lock to connect with a network controller.
All Code Lockout Mode:
This feature is enabled by the Master code. When enabled, it restricts all user (except Master)
PIN code access. When attempting to enter a code while the unit is in Lockout, the RED locked padlock will appear on
the screen.
Handing the Lock:
Lock handing refers to which direction the bolt comes out of the door (right or left). If the lock was
programmed off the door, the lock may need adjusting. Review Handing the Lock instructions and/or Re-Handing
instructions listed in Hardware Troubleshooting.
Содержание Assure Lock YRC256
Страница 8: ...Changing Handing if necessary continued 3 8 P N YRL EMICL 256 KFTSINSTL FUL Rev A...
Страница 14: ...14 P N YRL EMICL 256 KFTSINSTL FUL Rev A 8 Installing Lock Chassis 10 32 x 1 1 2 PPHMS Inside of Door x2 UP...