80-9350-2531-010 Rev 2 02/23
Copyright © 2016, 2023 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or in part without the express written permis-
sion of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
5
50 Series
Non-Hold Open Closer
2. Close latch and sweep valves.
3. Install soffit plate and mount closer.
4. Remove arm shoe and install forearm to
plate.
5. Place main arm on closer spindle and rotate
x4
or
x4
or
IMPORTANT
50 Series Parallel Arm Installation (Right Hand Shown)
1. Prepare door and frame.
9-1/16
(230)
3/4
(19)
Top of
Door
1-1/2
(38)
3-1/4
(83)
7
(178)
1/2
(13)
1/2
(13)
Hole for 214 Plate
only
4
(102)
7/16
(11)
2-1/8
(54)
2-3/4
(70)
2
(50)
3/8
(10)
Frame
A
CL
B
C
Door
Opening
Dimension
“A”
Dimension
“B”
Dimension
“C”
to 100°
9-1/4 (235)
7-5/8 (194)
8-5/8 (219)
101° to 130°
7-3/4 (197)
6-1/8 (156)
7-1/8 (181)
*
131° to 180°
5-3/4 (146)
4-1/8 (105)
5-1/8 (130)
*
Door/Wall/Hardware/Jamb conditions permitting
1st
2nd
Approved 2023-02-24