80-9350-2531-010 Rev 2 02/23
Copyright © 2016, 2023 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or in part without the
express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
4
50 Series
Non-Hold Open Closer
L
Y
S
Z
R
x2
or
2. Mount closer to frame.
x4
or
The
50 Series Non Hold Open Closer - Top Jamb Mount
has now been installed.
🛑
Go to page 2 for closer adjustments and decorative cap or cover installation.
RH and LH:
Position flat at S
3. Choose arm placement in shoe and install separate arms.
4. Connect arms and install
forearm screw.
5. Preload spring and tighten forearm screw.
1st
2nd
Rotate elbow until
Connecting Rod is
perpendicular to frame.
Rotating arm preloads
closer spring power.
1st
2nd
50 Series Top Jamb Arm Installation (Right Hand Shown)
1. Prepare door and frame.
Opening
Dimension “A”
to 100°
7-1/2 (191)
101° to 120°
6 (152)
*
121° to 180°
3-1/2 (89)
*
Door/Wall/Hardware/Jamb conditions permitting
9-1/16
(230)
3/4
(19)
Top of
Door
1-1/2
(38)
1-3/4
(44)
6
(152)
1/2
(13)
A
CL
A longer connecting rod
is required for reveals
greater than 3" (76mm)
Reveal
or
+
7-1/2%
Stronger
–
7-1/2%
Weaker
or
Approved 2023-02-24