Application environment and parameters 

Cooling way 

Natural cooling or radiator 

 

Application 

environment 

workplace 

Avoid dust, grease and 

corrosive gas 

Temperature 

0

50

 

Humidity 

40

90%RH 

Vibration 

5.9 m/s

2

 Max 

Save temperature 

-20

+80

 

Weight 

1500

 

3

Installation size 

                                

 

4

Strengthen cooling ways   

1

  The suitable temperature for driver is within 60

, while the suitable 

temperature for motor is 80

   

2

  When installing the driver, please use vertical profiles, which can form 

strong cross-ventilation; if necessary, install  a fan near the driver to make 

sure the driver works in suitable temperature. 

 

三、

Introduction of driver’s terminals and wiring 

1. Terminals 

 

 

 

Power

 

input 

terminal 

 

 

 

 

 

 

 

Motor output 

terminal 

 

Display

 

 

Control signal 

terminal

 

 

 

 

 

 

Encoder 

feedback 

terminal

 

Содержание MS - L3P

Страница 1: ...mechanical and environmental indicators 2 1 Electrical indicators 2 2 Application environment and parameters 3 3 Installation size 3 4 Cooling way 3 Introduction of driver s terminals and wiring 3 1 W...

Страница 2: ...n can be any value between 400 60000 Protection of over current over voltage under voltage and trace error etc 6 bits of digital tube display which is easy to set parameters and monitor motor s runnin...

Страница 3: ...20 80 Weight 1500 3 Installation size 4 Strengthen cooling ways 1 The suitable temperature for driver is within 60 while the suitable temperature for motor is 80 2 When installing the driver please us...

Страница 4: ...tor s encoder with driver through encoder cable 4 Definition of control signal terminal Connection of cables and signals as below Cable color Terminal No Terminal nameTerminal instruction Instruction...

Страница 5: ...e it will display one by one and it can save 10 latest errors in the driver EEPROM Menu display 1 Display interface MS LxP display interface has 4 keys they are up down move cancel and Enter As follow...

Страница 6: ...1 Memory read error 02 Over voltage protection 03 Under voltage protection 04 Encoder error 05 IPM error 06 Driver s over temperature protection 07 Position over error protection dP VEr Software versi...

Страница 7: ...will show Err and the errors code 0 13 1Rated speed 2 Current position high 4 bits 3 current position low 4 bits 4 position order high 4 bits 5 position order low 4 bits 6 position deviation high 4 bi...

Страница 8: ...larger the value the bigger the stiffness 1000 0 1000 PA 7 1 speed section 1 In different speed section the adjustments on resonance suppression help to eliminate vibration 942 0 60000 PA 7 2 resonan...

Страница 9: ...nd then restart the driver For other parameters don t need to restart the driver after changing 4 Test Run Sr You can only use this menu when parameter PA 2 is 1 Level 1 menu Level 2 menu Function Sr...

Отзывы: