Figure -3
CONNECTION DIAGRAM OF
ELECTRICL
CABLE TO CIRCULATION
PUMP
Figure -4
3 -
OPERATING CENTRAL HEATING STOVE
3.1
When installation becomes completed,
you must open the valve in order to give water to boiler's return
line (Figure
-
2/9) from
service water
line.
3.2
Valve must be closed when 1/4 of expansion tank is filled.
3.3
Empty
cable ends
must
be
connected
to
circulation pump (Figure
-
2/3)
as seen
in
(Figure
-
3)
3.4
Plug must be inserted to grounded socket. One of the lamps (from two
lamps
-
Figure
-
3/10) show
that there is electricity and the other
one
indicated that
electricity comes to
circulation pump (Figure
-
2/3). Operating of circulation pump is
provided by adjusting the thermostat of pump (Figure
-
2/11)
to
zero degree.
3.5 By removing big yellow
screw on
the circulation pump, be
sure that the
tip of
motor
shaft taking
place
inside turns. If it is not turning, shaft must be turned
once
with the screwdriver. Big yellow screw is
applied
to
its
place
when
shaft
starts to turn.
3.6
Air of the
cores
must
be removed. Water level of expansion tank must be controlled.
3.7
Water
is
given
to
the
system from
boiler's inlet pipe (Figure
-
2/9)
from
service
water line.
3.8 After
becoming
sure
that there is
no
leakage in the system, fuel is loaded to the firing chamber and
then the
fire is set. Pump thermostat (Figure
-
3/10) is adjusted. Pump will start working when the
temperature of the
water
exceeds 40°C.
3.9 Temperature of
the boiler's water
(which is determinant for the temperature of the room) is adjusted
from
chain
driven thermostatic
regulator (Figure
-
2/6). Chain driven thermostatic regulator automatically
controls
burning speed of Central Pleating Stove and
it maintains the heat of the water fixed at the
adjusted temperature.
3.10 In order to obtain
a
good heat, coal must be preferred by having 6.000-7.000
kcal/hour value, having
less ash residue and
it must be dry and without dust and must have orange and walnut size. Big
coal comforts air
inlet.