[CO)] Switch
[CONTRAST(–)] Switch
P
HASE
I
NVERSION
When the received audio phase is reversed, the
SM-5000
gives depth to the audio sound.
1. If needed, press both [
CONTRAST
(
+
)] and [
CON-
TRAST
(
–
)] switches to change the adjustment mode to
“Audio Setting”.
The Audio Setting window will appear on the display.
Note
: Pressing of the
[
CONTRAST
(
+
)]/[
CONTRAST
(
–
)]
switch will store the last selected “Contrast Setting Mode”
or “Audio Setting Mode” to memory.
2. Press the [
CONTRAST
(
+
)] switch to toggle the audio
phase “
ON
(reversed phase)” or “
OFF
(normal response)”.
3. A few seconds after pressing the [
CONTRAST
(
+
)]
switch, the Audio Setting window will close.
A
UDIO
S
ETTING
A
DJUSTING
THE
C
ONTRAST
You may adjust the contrast for best viewing in sunlight, dusk, or night allowing for best readability.
1. If needed, press both [
CONTRAST
(
+
)] and [
CON-
TRAST
(
–
)] switches to change the adjustment mode to
“LCD Contrast Setting”.
The Contrast window will appear on the display.
Note
: Pressing of the
[
CONTRAST
(
+
)]/[
CONTRAST
(
–
)]
switch will store the last selected “Contrast Setting Mode”
or “Audio Setting Mode” to memory.
2. Press the [
CONTRAST
(
+
)] switch to increase the con-
trast of the display.
3. Press the [
CONTRAST
(
–
)] switch to reduce the contrast
of the display.
4. A few seconds after pressing the [
CONTRAST
(
+
)]/
[
CONTRAST
(
–
)] switch, the Contrast window will close.
S
PECTRUM
S
COPE
D
ISPLAY
“ON/OFF”
You may turn off the Spectrum Scope Display.
1. Press and hold the
FT
DX
5000
[
C.S
] key for 2 seconds to
engage the Scope Menu mode.
The
SUB DISPLAY-
I
window will show the Group name
(
SCOPE
), while the
SUB DISPLAY-
II
window will show
the Menu item. The
SUB DISPLAY-
III
window shows
the current setting of the currently-selected Menu item.
2. Rotate the (
VFO-A
)[
SELECT
] knob to select the Menu
item “
DISPLAY
”, then rotate the (
VFO-B
)[
SELECT
]
knob to select “
OFF
”.
The Spectrum Scope Display turns off.
3. Press the [
C.S
] key briefly to save the new setting and
exit to normal operation.
To turn the Spectrum Scope Display on, repeat the above pro-
cedure, rotating the (
VFO-B
)[
SELECT
] knob to select “
ON
”
as in step “2” above.
D
ISPLAY
S
ETTING
[CO)] Switch
[CONTRAST(–)] Switch
(VFO-A)[SELECT] Knob
(VFO-B)[SELECT] Knob
[C.S] Switch
When the
FT
DX
5000
[
DIM
] button is pressed, the il-
lumination level of the
SM-5000
will also be reduced.
The amount of brightness may be set via
FT
DX
5000
Menu item “
011 DISP DIM ELCD
”.
D
ISPLAY
D
IMMER
A
DVICE
:
When a contrast level is too high, it is difficult to watch the
“Average” and “Peak hold” indication (See page 3).