 Installation of Rotator and Antenna on Tower

The procedure for installing the rotator depends on the type of tower used. The following instruc-
tions are generally applicable to most guyed, crank-up, or roof towers.

1. Attach the rotator to the tower’s rotator mounting plate, using the supplied M8X16 bolts and

spring washers. It is recommended that the tips of the bolts be lightly dipped in lubricating grease,
to ease disassembly in the future.

2. If a thrust bearing (such as the optional Yaesu model GS-065) is to be utilized, mount it on the top

of the tower (see Figure 4) using the supplied hardware.

3. Using a “gin pole” or other raising fixture, insert the antenna mast through the bearing from

above, and set the mast in the rotator’s mast clamps. Do not tighten the mast clamps at this time;
just secure the U-bolts to the point where the mast is held in place, but is allowed to rotate freely.

4. Partly tighten the thrust bearing’s mast bolts, so as to center the mast in the thrust bearing. When

you are satisfied that the mast is centered, back off slightly on each of the thrust bearing’s mast
bolts, and (if possible) lift the mast by a 

very small amount

 (approximately 5 mm or 3/16”), just

enough to lift the bottom of the mast slightly off the top of the rotator. Now re-tighten the thrust
bearing’s mast bolts to secure the mast in place. This procedure takes all the weight of the mast
and antennas off of the rotator; all weight is being carried by the thrust bearing. If no thrust
bearing is used, the mast should be allowed to rest on the top of the rotator.

5. Verify that the mast rotates freely in the mast clamps, and that the mast is properly centered in the

clamps. Now tighten the nuts on the U-bolts of the mast clamp.

Do not over-tighten the nuts on the mast clamps. They should be tightened until the
spring washer becomes flat, then tightened further by ½ to one turn maximum.

6. Install the rotator control cable’s round plug into the jack on the side of the rotator’s base, and

tighten the connector ring to secure the connector. Slide the rubber boot over the connector; while
putting a slight amount of inward pressure on  the rubber boot, use electrical tape to secure the
back end of the rubber boot to the cable. This slight inward pressure on the rubber boot will
enhance the weatherproofing of the installation. Secure the control cable to the tower in several
places, using electrical tape and/or UV-resistant cable ties.

7. Install the antenna(s) on the mast. Use a compass to align the forward end of the beam toward

North (0º) 

or whichever direction to which you set the “Left Stop” in Step 12 of the previous

section

.

8. Provide sufficient slack in the coaxial cable such that the antenna can rotate over its full 450º

range without putting 

any

 tension on the coax (see Figure 8). Secure the coax to the tower, using

electrical tape and/or UV-resistant cable ties.

9. Installation is now complete. If you have scratched through the melamine coating of the rotator

during installation, you may wish to apply several coats of clear acrylic spray to help protect the
bare metal from corrosion.
After installation is complete, test the system by operating the rotator through the entire range of
its rotation. It is helpful to do so with the help of an observer, so that rotation can be stopped if
some obstruction, binding, or tension on the coaxial cable’s turning loop should be encountered
during the performance test.

Installation Note

If using a roof tower with a long mast between the top of the tower and the antenna, the use of a
“Guy Bearing” is highly recommended. The Yaesu GS-050 and GS-065 include guying “ears”
which allow attachment of guy cables. As installing a guying system may cause the center-lines of
the guy bearing and the rotator to become mis-aligned, be certain to check the roof tower attach-
ment and guy cable alignment to ensure that the mast is straight.

C

AUTION

9

Содержание G-650A

Страница 1: ...Cerritos CA 90703 U S A YAESU EUROPE B V Snipweg 3 1118DN Schiphol The Netherlands YAESU UK LTD Unit 12 Sun Valley Business Park Winnall Trading Estate Winchester Hampshire SO23 0LB U K YAESU GERMANY...

Страница 2: ...center protrudes by f48 to f52 Rotation Range 450 360 Rotation Time 63 seconds at 50 Hz 51 seconds at 60 Hz Braking Type Mechanical stopper Mechanicalandelectricalstoppers Antenna K Coefficient 100 1...

Страница 3: ...tion can be achieved using the optional GL 33 mast adjustment plate per the illustrations below Mast Diameter f32 to f38 Use two plates Mast Diameter f39 to f47 Use one plate Mast Diameter f48 to f50...

Страница 4: ...Controller Front Rear Panel Controls and Switches Controller Front Panel Controller Rear Panel When replacing fuses be sure to use a fuse of the same type and current rating 2...

Страница 5: ...Attachment Plate Dimensions The tower plate onto which the rotator unit is mounted must be drilled with four holes of 9 mm diameter equally spaced on a circle of 119 mm diameter The center to center...

Страница 6: ...antenna of surface area of 0 3 m2 see Table 1 the above specifications for pole mounting will be met if A the antenna is mounted on a mast not longer than 0 8 m 0 3 0 8 0 24 0 25 and B if the mast we...

Страница 7: ...arately for each an tenna using the relative heights of the two antennas to apportion the mast weight The antenna system K factor then is the sum of the two antenna K factors K1 K factor of 14 MHz 3 e...

Страница 8: ...used Confirm that all solder joints are firm and cleanly made as this part of the cable will be difficult to access once the rotator is installed on top of the tower Do not slide the shell onto the c...

Страница 9: ...Assembly of 6 pin Plastic Connector Assembly of 7 pin Metal Connector Wiring for the control cable identical numbers to be inte Pin No 7 for the metal connector is not used 7...

Страница 10: ...be pointing exactly to 0 If the indicator needle is not pointing exactly to 0 go to the rear panel of the controller and set the Adjustment Potentiometer Selection Switch see Figure 2 to the right po...

Страница 11: ...ightened further by to one turn maximum 6 Install the rotator control cable s round plug into the jack on the side of the rotator s base and tighten the connector ring to secure the connector Slide th...

Страница 12: ...Figure 8 Figure 7 Figure 5 Figure 3 M8 16 length 16 mm Spring washer Thrust Bearing GS 065 option Must be parallel Antenna mast Provide sufficient slack More than 1 m Less than 1 m Mast Bearing GS 06...

Страница 13: ...nstallation See your dealer for details of available lightning protection devices If an electrical storm should be reported in your area quickly unplug the control cable from the rear of the rotator s...

Страница 14: ...NOTE 12...

Страница 15: ...Copyright 1998 Yaesu Musen Co Ltd All rights reserved No portion of this manual may by reproduced without the permission of Yaesu Musen Co Ltd...

Отзывы: