G-800SA/G-1000SA User Manual
Page 6
I
NDOOR
P
ERFORMANCE
C
HECK
AND
A
LIGNMENT
base of the rotator unit, and make a calibration mark
will be used to verify the amount of rotation in the
next step.
8.
Press the
RIGHT
(rotation) side of the seesaw switch,
and continue rotating to the right until the calibra-
tion marks (from step 7) are again precisely aligned.
Now check the indicator needle, which should also
have rotated fully 360° so as to be pointing exactly
to 180°.
If the indicator needle is not pointing exactly to 180°,
go to the rear panel of the controller, and use a small
screwdriver to adjust the
FULL SCALE ADJ
po-
tentiometer (see the drawing to the right) so that the
indicator needle points exactly to 180°.
9.
Press the
RIGHT
switch again, and continue rota-
tion to the right. You should observe the
OVER-
LAP
LED becoming illuminated as rotation passes
the 180° point.
If the
OVERLAP
LED does not light up at the 180°
position, the
OVERLAP LED ADJ
potentiometer
(on the rear panel of the controller) may be used to
align the illumination threshold to the 180° point.
10. Check to verify that rotation automatically stops at
approximately 270° (West; representing a total ro-
tation range of 450° from the original starting point).
11. Press the
LEFT
and
RIGHT
(rotation) switches a
few more times, verifying that rotation appears to
be normal. If so, press the
LEFT
or
RIGHT
(rota-
tion) switch to set the rotator to 270° (West).
12. Set the
SELECT SWITCH
on the rear panel to the
left
(
OPERATION MODE
) position, and turn the
POWER
switch “OFF.”
13. This completes the ground-based testing of the ro-
tator and controller.
Mounting the Rotator and Antenna
1.
Temporarily connect the control cable between the
rotator unit and the controller.
2.
Set the
SELECT SWITCH
on the rear panel to the
right
(
ADJ. MODE
) position.
3.
Check to be sure that the
POWER
switch on the
controller is set to “OFF,” then plug the controller’s
AC cable into your station’s AC outlet.
4.
Set the controller’s
POWER
switch to “ON.” The
pilot lamps on the controller should become illumi-
nated, and the meter needle on the controller may
rotate so as to align itself with the current position
of the rotator (remember the two units have not been
aligned with each other).
5.
Press the
LEFT
(rotation) side of the seesaw switch,
and continue to hold it until the rotator reaches the
counter-clockwise position where it automatically
stops (“Left” represents counter-clockwise rotation
when the rotator is viewed from the top).
6.
When the rotator has reached the left “stop” posi-
tion, release the
LEFT
switch, and check to see if
the controller’s indicator needle is pointing to 180°
(S: South).
If the indicator needle is out of alignment, grasp the
edge of the bezel around the bearing window, turn it
10 ° counter-clockwise, and pull it off. Then, grasp
the needle at its center and pull it straight off, re-
place the needle to 180° (straight down), and replace
the bezel.
7.
Just above the round connector jack on the rotator
unit, you will observe two raised calibration marks
(one each on the “rotating” bell and “fixed” base of
the rotator). These two marks should be directly
aligned with each other. If not, place a small piece
of masking tape on the rotating bell and the fixed
Controller Rear Panel