19
C
OMMAND
L
IST
O
PERA
TION
Returned by
[
H
]
Command:
--------- - COMMAND LIST 1 ----------
R
Clockwise Rotation
L
Counter Clockwise Rotation
A
CW/CCW Rotation Stop
C
Antenna Direction Value
M
Antenna Direction Setting. MXXX
M
Time Interval Direction Setting.
MTTT XXX XXX XXX -- -
(TTT = Step value)
(XXX = Horizontal Angle)
T
Start Command in the time interval direction setting
mode.
N
Total number of setting angles in “M” mode and traced
number of all datas (setting angles)
X 1
Rotation Speed 1 (Horizontal) Low
X 2
Rotation Speed 2 (Horizontal) Middle 1
X 3
Rotation Speed 3 (Horizontal) Middle 2
X 4
Rotation Speed 4 (Horizontal) High
S
All Stop
O
Offset Calibration
F
Full Scale Calibration
Returned by
[
H2
]
Command:
--------- - HELP COMMAND 2 ----------
U
UP Direction Rotation
D
DOWN Direction Rotation
E
UP/DOWN Direction Rotation Stop
C 2
Antenna Direction Value
W
Antenna Direction Setting.
WXXX YYY
W
Time Interval Direction Setting.
WTTT XXX YYY XXX YYY ---
(TTT = Step value)
(XXX = Horizontal Angle)
(YYY = Elevation Angle)
T
Start Command in the time interval direction setting
mode.
N
Total number of setting angle in “W” mode and traced
number of all datas (setting angles)
S
All Stop
0 2
Offset Calibration
F2
Full Scale Calibration
B
Elevation Antenna Direction Value