75
Using the APRS set-up menu
15
Turn the DIAL, select
[5 FAST RATE]
, and press
.
Move the cursor over the item for which you would
like to enter numbers.
Set the beacon transmission time interval for when the speed exceeds the speed set
under “3 HIGH SPEED”.
16
Refer to steps7 - 9 to set the time, then press
.
A time between 10 min and 180 min can be set.
Tip
Factory default value: 120 sec
17
Turn the DIAL, select
[6 TURN ANGLE]
, and press
.
Move the cursor over the item for which you would
like to enter numbers.
Set the minimum angle for determining whether the direction of advance has
changed.
18
Refer to steps 7 - 9 to set the angle, then press
.
An angle between 5° and 90° can be set.
Tip
Factory default value: 28°
19
Turn the DIAL, select
[7 TURN SLOPE]
, and press
.
Move the cursor over the item for which you would
like to enter numbers.
Set the coefficient for dynamically changing the angle that is used to determine
changes in the direction of advance depending on the movement speed. The larger
the coefficient value, the larger is the criteria angle at low speeds.
1 - 255 (X10)°/speed
(the unit for the rotating tilt is set to one-tenth of the real number so as to be
consistent with the unit used in the HamHUD series from HamHUD Nichetronix).
20
Refer to steps 7 - 9 to set the coefficient, then press
.
A value between 1 and 255 can be set.
Tip
Factory default value: 26
21
Turn the DIAL, select
[8 TURN TIME]
, and press
.
Move the cursor over the item for which you would
like to enter numbers.
Set the time limit until the next beacon can be sent after a beacon has been
transmitted due to a change detected in the time (Variable Rate Beaconing) and
direction of advance (Corner Pedding).
22
Refer to steps 7 - 9 to set the time limit, then press
.
A time between 5 sec and 180 sec can be set.
Tip
Factory default value: 30 sec