FT
DX
1200 Technical Supplement
Alignment
ALIGNMENT-1
Introduction and Precautions
The following procedures cover adjustments that
are not normally required once the transceiver
has left the factory. However, if a problem occurs
during normal operation due to component failure;
realignment may be required after the faulty com-
ponents have been replaced.
We recommend that authorized Yaesu Techni-
cians, who are experienced with the circuitry and
fully equipped to repair and align our products,
perform repairs. If a fault is suspected, contact the
selling dealer for instructions regarding repair.
Authorized Yaesu Technicians have the latest infor-
mation to align all circuits and make complete per-
formance checks to ensure compliance with factory
specifications after repairs.
Those who do undertake any of the following
alignments are cautioned to proceed at their own
risk. Problems caused by unauthorized attempts at
realignment are not covered by the warranty poli-
cy.
Yaesu must reserve the right to change circuits and
alignment procedures in the interest of improved
performance, without notifying owners.
Under no circumstances should any alignment be
attempted unless the normal functions and opera-
tion of the transceiver are clearly understood, the
cause of the malfunction has been clearly identified
and all faulty components replaced. The need for
realignment should be determined to be absolutely
necessary.
The following test equipment (and a thorough fa-
miliarity with its correct use) is necessary for cor-
rect realignment. Most steps do not require all of
the equipment listed. The interactions of some ad-
justments may require that more complex adjust-
ments be performed in a sequence. Do not attempt
to perform only a single step unless it is clearly iso-
lated electrically from all other steps. Have all test
equipment ready before beginning, and follow all
of the steps in a section in the order they are pre-
sented.
Required Test Equipment
RF Signal Generator
AF Signal Generator
Spectrum Analyzer good to at least 1 GHz.
Frequency Counter
SINAD Meter
RF Millivoltmeter
Electronic Load
Digital DC Voltmeter (high-Z, 1 M-Ohm/V)
DC Voltmeter
DC Ammeter (20 A)
Ohmmeter
50-Ohm Dummy Load (100/200 watts)
In-Line Wattmeter (150/300 watts, 50-Ohm)
Linear Detector
RF Coupler
4-Ohm AF Dummy Load (3 watts)
1/4-inch 3-contact Plug
Alignment Preparation & Precautions
A 50-ohm RF Dummy load and in-line wattmeter
must be connected to the “ANT 1” jack in all proce-
dures that call for transmission, except where spec-
ified otherwise. Correct alignment is not possible
with an antenna.
After completing one step, read the following step
to determine whether the same test equipment
will be required. If not, remove the unneeded test
equipment before proceeding. (except the dummy
load and wattmeter).
Correct alignment requires that the ambient tem-
perature be maintained constant between 68 °F ~ 86
°F (20 °C ~ 30 °C). When the transceiver is brought
into the shop from a hot or cold environment, it
should be allowed time to come to room tempera-
ture before alignment. Also, the test equipment
must be thoroughly warmed up before beginning.
Whenever possible, alignments should be made
with oscillator shields and circuit boards firmly af-
fixed in place.
Note
: Signal levels in dB referred to in this proce-
dure are based on 0 dBµ = 0.5 µV (closed cir-
cuit).
Important Notice
Do not adjust the alignment menus that are
not mentioned in this manual.
Содержание FTDX1200 Series
Страница 10: ...BLOCK DIAGRAM 1 FTDX1200 Technical Supplement Block Diagram ...
Страница 11: ...CONNECTION DIAGRAM 1 FTDX1200 Technical Supplement Connection Diagram ...
Страница 31: ...FTDX1200 Technical Supplement MAIN 1 MAIN Unit Circuit Diagram ...
Страница 32: ...FTDX1200 Technical Supplement MAIN 2 A B C D E F G H 1 2 3 4 5 6 MAIN Unit Parts Layout side A ...
Страница 33: ...FTDX1200 Technical Supplement MAIN 3 MAIN Unit Parts Layout side B a b c d e f g h 1 2 3 4 5 6 ...
Страница 57: ...FTDX1200 Technical Supplement CNTL 1 CNTL Unit Lot 1 3 Circuit Diagram ...
Страница 58: ...FTDX1200 Technical Supplement CNTL 2 A B C D E F G H 1 2 3 CNTL Unit Lot 1 3 Parts Layout Side A Side B ...
Страница 59: ...FTDX1200 Technical Supplement CNTL 3 CNTL Unit Lot 4 Circuit Diagram ...
Страница 60: ...FTDX1200 Technical Supplement CNTL 4 CNTL Unit Lot 4 Parts Layout Side A Side B A B C D E F G H 1 2 3 ...
Страница 67: ...FTDX1200 Technical Supplement LOCAL 1 LOCAL Unit Circuit Diagram ...
Страница 68: ...FTDX1200 Technical Supplement LOCAL 2 A B C D E F G 1 2 3 LOCAL Unit Parts Layout Side A ...
Страница 69: ...FTDX1200 Technical Supplement LOCAL 3 LOCAL Unit Parts Layout Side B ...
Страница 76: ...FTDX1200 Technical Supplement PA 1 PA Unit Circuit Diagram ...
Страница 77: ...FTDX1200 Technical Supplement PA 2 A B C D E F 1 2 3 4 5 7 6 8 PA Unit Parts Layout side A ...
Страница 78: ...FTDX1200 Technical Supplement PA 3 PA Unit Parts Layout side B ...
Страница 85: ...FTDX1200 Technical Supplement TUNER 1 TUNER Unit Lot 1 2 Circuit Diagram ...
Страница 86: ...FTDX1200 Technical Supplement TUNER 2 A B C D E F G H 1 2 3 TUNER Unit Lot 1 2 Parts Layout Side A Side B ...
Страница 87: ...FTDX1200 Technical Supplement TUNER 3 TUNER Unit Lot 3 Circuit Diagram ...
Страница 88: ...FTDX1200 Technical Supplement TUNER 4 A B C D E F G H 1 2 3 TUNER Unit Lot 3 Parts Layout Side A Side B ...
Страница 93: ...FTDX1200 Technical Supplement DSP 1 DSP Unit Circuit Diagram ...
Страница 94: ...FTDX1200 Technical Supplement DSP 2 A C E D 1 2 3 DSP Unit Parts Layout Side A B ...
Страница 95: ...FTDX1200 Technical Supplement DSP 3 DSP Unit Parts Layout Side B a c e d 1 2 3 b ...
Страница 101: ...FTDX1200 Technical Supplement DISPLAY 1 1 DISPLAY 1 Unit Circuit Diagram ...
Страница 102: ...FTDX1200 Technical Supplement DISPLAY 1 2 A C D 1 2 3 DISPLAY 1 Unit Parts Layout Side A B ...
Страница 103: ...FTDX1200 Technical Supplement DISPLAY 1 3 DISPLAY 1 Unit Parts Layout Side B A C E D F 1 2 4 3 B ...
Страница 109: ...LED 1 LED Unit Circuit Diagram Parts Layout Side A Side B FTDX1200 Technical Supplement ...
Страница 111: ...FTDX1200 Technical Supplement SW A 1 SW A Unit Circuit Diagram ...
Страница 112: ...FTDX1200 Technical Supplement SW A 2 SW A Unit Parts Layout Side A Side B ...
Страница 115: ...FTDX1200 Technical Supplement SW B 1 SW B Unit Circuit Diagram ...
Страница 116: ...FTDX1200 Technical Supplement SW B 2 SW B Unit Parts Layout Side A Side B ...
Страница 118: ...VR A 1 VR A Unit Circuit Diagram Parts Layout Side A Side B FTDX1200 Technical Supplement ...