background image

FTA-250L O

perATing

 M

AnuAL

1

Introduction

The YAESU 

FTA-250L

 is ultra compact, stylish, solid hand-held transceivers providing communication (transmit 

and receive) capability on the International Aircraft Communication Band (“COM” band: 118 to 136.975 MHz).
The 

FTA-250L

 includes NOAA weather band monitoring and 250 memory channels. The channel configurations 

can be easily reprogrammed in minutes using the optional PC Programming Software and your PC.
We recommend that you read this manual in its entirety, so as to understand the many features of the 

FTA-250L

 

completely. Keep this manual handy, so you may use it for reference.

Congratulations!

You now have at your fingertips a valuable communications tool, a YAESU two-way radio! Rugged, reliable 

and easy to use, your YAESU radio will keep you in constant touch with your friends and colleagues for 

years to come, with negligible maintenance or downtime.
Please take a few minutes to read this manual carefully. The information presented here will allow you to 

derive maximum performance from your radio, in case questions arise later on.
We’re glad you joined the YAESU team. YAESU products cover the entire spectrum of radio communica-

tions applications, and our worldwide support network is here to serve you. Let us help you get your mes-

sage across.

Содержание FTA-250L

Страница 1: ...Operating Manual AIR BAND TRANSCEIVER FTA 250L F...

Страница 2: ...emory channels 8 Call the emergency communication frequency 121 5 MHz 8 Controls Connectors Top Front Panel 9 Controls Connectors Left Right Side 10 Operation 11 Using comm mode 13 Using memory mode 1...

Страница 3: ...FTA 250L completely Keep this manual handy so you may use it for reference Congratulations You now have at your fingertips a valuable communications tool a YAESU two way radio Rugged reliable and eas...

Страница 4: ...t in an accident Do not use this product while riding a bicycle or driving a car Ac cidents can result Be sure to stop the bicycle or car at a safe place before using this product Do not perform trans...

Страница 5: ...not being used for an extended period turn it off and remove the battery pack for safety Do not drop strike or throw the transceiver A failure or damage may result Keep magnetic cards and videotape aw...

Страница 6: ...he Measurement of Potentially Hazardous Electromagnetic Fields RF and Microwave This radio is NOT approved for use by the gen eral population in an uncontrolled environment This radio is restricted to...

Страница 7: ...50 mAh SBR 25LI Li Ion Battery Pack 7 4 V 2 500 mAh SBR 26LI AC Adapter SAD 20 Charger Cradle SBH 22 Cigarette Lighter DC DC Converter SDD 12 Helical Antenna SRA 18A Belt Clip SHB 18 Headset Adapter C...

Страница 8: ...tion Attach the belt clip on the back of transceiver using the supplied screws two Installing the Battery Pack 1 Insert the battery pack into the battery c o m p a r t m e n t o n t h e b a c k o f t...

Страница 9: ...en the SBH 22 LED lights in green Charge the battery pack in a place where the ambient temperature is 41 F to 95 F 5 C to 35 C AC line outlet SAD 20 SBH 22 DC IN jack Charging with external power cabl...

Страница 10: ...y to select the Channel Press and hold the ENT key Press and hold the ENT key again Recall a memory channel Press the GROUP key Press the GROUP key to select the Group Press the DWN or UP key to selec...

Страница 11: ...nel F Antenna Jack BNC LOCK Key Press and hold to turn the lock function ON OFF PWR VOL Knob Power ON OFF Volume adjustment Loudspeaker Microphone TX indicator Lights red during transmission LCD Liqui...

Страница 12: ...Adapter Cable may be connected to this jack EXT DC Jack The SDD 12 Cigarette Lighter DC DC Converter may be connected to this jack Controls Connectors Left Right Side PTT Push To Talk Switch Flip Flop...

Страница 13: ...e l e c t s t h e d e s i r e d operating mode DWN key COMM mode GROUP key MEMORY mode UP key WX mode COMM mode Set the desired frequency and operate MEMORY mode The 250 memory channels can register...

Страница 14: ...ssigned the memory channel frequency is displayed Group number Displays the memory channel group number Channel in use Channel not in use Channel number Displays the memory channel number Memory scan...

Страница 15: ...by pressing the PTT switch before completing the entry z z Register frequently used frequencies into the memory channels The memory channel may be easily recalled for later use page 14 Using memory m...

Страница 16: ...te the nametag 7 Press and hold the ENT key Frequency and name are registered and operation is returned to the normal operation screen Recalling the Memories 1 Press the MAIN SET key 2 Press the GROUP...

Страница 17: ...ed by entering frequencies from the keyboard WX01 162 550 MHz WX06 162 500 MHz WX02 162 400 MHz WX07 162 525 MHz WX03 162 475 MHz WX08 161 650 MHz WX04 162 425 MHz WX09 161 775 MHz WX05 162 450 MHz WX...

Страница 18: ...the right illustrates setting the SQL level The six default functions and the displayed Icons are described below SQL Setting the squelch level page 22 KEY BEEP Setting the loudness of key beeps SCAN...

Страница 19: ...H page 20 NONE No Function is assigned Program the function assigned to the function key To change a function to be recalled with the FUNC key 1 Press and hold the MAIN SET key GROUP Press the DWN q t...

Страница 20: ...Y mode scanning searches for a frequency or memory chan nel that is receiving a signal 1 P r e s s a n d h o l d t h e DWN or UP key to start scanning z z Press and hold the DWN key Scan to lower freq...

Страница 21: ...change contents are registered and the changed memory channel is evaluated is not displayed Scanning will be skipped is displayed Scanning is not skipped Maintenance of the Memory The group channel n...

Страница 22: ...o move to the right digit 8 Repeat steps 6 to 7 to complete the nametag 9 Press and hold the ENT key Changes are registered and the changed memory channel is displayed Dual Watch feature The previousl...

Страница 23: ...n also transmit on the PRIORITY CH z z When the signal on the PRIORITY CH drops out the dual watch resumes 3 Press the FUNC key and then press the GROUP key to stop the dual watch function and re turn...

Страница 24: ...witch PWR VOL knob 121 5 key and LOCK key cannot be locked 2 To cancel the lock press and hold the LOCK key until UNLOCK appears on the display Previous Frequency and Memory Recall Feature Up to nine...

Страница 25: ...n settings Make settings related to the operation of the radio Display firmware version 3 Press the DWN or UP key to select the item to be set and then press the GROUP key 4 Press the DWN or UP key to...

Страница 26: ...he PTT switch during scanning ON OFF ON SCAN RESUME Sets the scanning resume time after scan is tempo rally stopped by a received signal 1 2 3 4 5 SEC 3 SEC SCAN STOP TYPE Sets the condition of the sc...

Страница 27: ...NORMAL Output received voice as it is LO CUT Output reception sound cut low frequency HI CUT Output received voice cut high frequency HI LO CUT Output reception sound cut low and high range NORMAL VOX...

Страница 28: ...UNC key For details please refer to Program the function assigned to the function key on page 17 SQL KEY BEEP SCAN SCAN MEM DIM DISP RX NOISE DUAL WATCH NONE 1 SCAN 2 DUAL WATCH 3 SQL 4 KEY BEEP 5 RX...

Страница 29: ...FTA 250L Operating Manual 27 ABOUT Item Description Selectable options Default Value Confirming the version of the software...

Страница 30: ...t h e MAIN SET and ENT keys while turning the transceiver ON 3 Reset is complete when the sound beeps and the power turns on Headset Connection An optional headset may be connected using the supplied...

Страница 31: ...T Switch from Yaesu Contact your Aviation dealer for details regarding purchasing an aftermarket Push To Talk switch Will my headset work with this radio The SCU 15 headset adapter cable is made to op...

Страница 32: ...BR 25LI antenna and belt clip Receiver Circuit Type Double conversion superheterodyne IFs 47 25 MHz 450 kHz Sensitivity 0 8 V typ for 6 dB S N with 1 kHz 30 modulation Selectivity Better than 8 kHz 6...

Страница 33: ...f rieur approuv pour l metteur par Industrie Canada Dans le but de r duire les risques de brouillage radio lec trique l intention des autres utilisateurs il faut choisir le type d antenne et son gain...

Страница 34: ...Musen Co Ltd of Tokyo Japan hereby declare that this radio equipment FTA 250 is in full compliance with EU Radio Equipment Directive 2014 53 EU The full text of the Declaration of Conformity for this...

Страница 35: ......

Страница 36: ...oduced without the permission of YAESU MUSEN CO LTD YAESU MUSEN CO LTD Tennozu Parkside Building 2 5 8 Higashi Shinagawa Shinagawa ku Tokyo 140 0002 Japan YAESU USA 6125 Phyllis Drive Cypress CA 90630...