Page 76
FT-991 O
peraTing
M
anual
S
tAndArd
M
eMory
o
perAtion
The Standard Memory of the
FT-991
allows storage and recall of up to 99 memories, each storing frequency, mode,
and a wide variety of status information, detailed previously. Memories may be grouped into as many as six Memory
Groups, and additionally you get nine pairs of band-limit (PMS) memories along with five QMB (Quick Memory Bank)
memories.
Memory Storage
1. Set VFO-A up with the frequency, mode, and status,
the way you want to have it stored.
2. Press the
A
M
button momentarily; the current
channel number will start blinking in the display and
the “
MCK
” notation will appear.
3. Rotate the
MULTI
knob to select the memory chan-
nel that you wish to store the data on.
4. Press and hold in the
A
M
button for one second to
store the frequency and other data into the selected
memory channel. A double beep will confirm that
you have held the
A
M
button in long enough.
Memory Channel Recall
1. Press the
V/M
button, if necessary, to enter the
“Memory mode”.
2. Press the
F(M-LIST)
button, then touch [
MCH
] on
the LCD. A memory channel number and the “
MCH
”
notation will appear in the display.
3. After touching [
MCH
] on the LCD, you may rotate
the
MULTI
knob to select the desired memory chan-
nel.
A
dvice
:
To work within a particular Memory Group, press the
F(M-LIST)
button, then touch [
GRP
] on the LCD.
Rotate the
MULTI
knob to select the desired Memory
Group, then touch [
ENTER
] on the LCD (the “
MCH
”
notation will appear instead of the “
GRP
”); you may
now choose the memory channel within the selected
Memory Group.
F(M-LIST) Button
V/M Button
MULTI Knob
A
M Button
MULTI Knob
M
eMorY
o
peraTion
Содержание FT-991