60
Menu Operation
Menu Item 37 [MIC SCAN]
Function
: Enable/disable scanning access via the microphone’s [
UP
]/[
DWN
] keys.
Available Values
: OFF/ON
Default
: ON
Menu Item 38 [OP FILTER]
Function
: Enable the optional filter (CW or SSB) path.
Available Values
: OFF/SSB/CW
Default
: OFF
After installing the optional filter, set this Menu Item to define the signal path corresponding
top the filter you have installed.
Menu Item 39 [PKT MIC]
Function
: Adjust the audio input level from the TNC during 1200 bps Packet operation.
Available Values
: 0 ~ 100
Default
: 50
Menu Item 40 [PKT RATE]
Function
: Set the transceiver’s circuitry for the Packet baud rate to be used.
Available Values
: 1200/9600 bps
Default
: 1200 bps
Menu Item 41 [RESUME]
Function
: Set the delay time for scanning resumption.
Available Values
: OFF/3/5/10 seconds
Default
: 5 sec
When this Menu Item set to “OFF,” the scanner stops (without restarting) until you press
the
(SCN) key (or the microphone’s [
UP
]/[
DWN
] keys).
Menu Item 42 [RPT SHIFT]
Function
: Set the magnitude of the Repeater Shift.
Available Values
: 0 ~ 99.99 MHz
Default
: Depends on transceiver version, and the band in use.
Each band’s repeater shift (HF/50/144/430 MHz) may be set independently.
Menu Item 43 [SCOPE]
Function
: Select the Spectrum Scope mode.
Available Values
: CONT/CHK
Default
: CONT
CONT: The Spectrum Scope sweeps continuously.
CHK: The Spectrum Scope sweeps one cycle every 10 seconds.
Menu Item 44 [SIDETONE]
Function
: Adjust the CW sidetone volume level.
Available Values
: 0 ~ 100
Default
: 50