( 9 )
Set the B A N D sw itch at 80. V FO at 4 .000
K Hz.
and the PRESELECTOR at
7
of the inner scale
Set TCl and TC6 at the m id-capacitance point.
Tune the transceiver to 4 .0 00
K Hz
and adj ust
T105 and T106 for m aximum transm itter power
output into the load.
( 1 0 ) Set the OPERATION sw itch to the receive mode.
and without changing the V FO or P R ESELECTOR
settings. tune the RF sign al generator to 4 .000
KHz
and obtain a 1.000
Hz
beat note. Set TCl l to
the mid-capacitance point. A dj ust T 1 0 4 for maxi
mum audio out put as descri bed i n step 2.
( 11
)
Set the PRESELECTOR at the low er edge of the
80 meter segment. VFO at 3 . 5 00
K Hz.
and adj ust
TCl and TC6 for maximum transm itter power
output into the dummy load.
(J 2 ) Set the OPERATION sw itch to the receive mode.
( l OA)
TC20
( 1 0) TC 1 5
( I O) TC5
( 1 5) TC4
(20) TC3
L33
TC 1 8 (20)
TCl 7 (40)
TC 1 2 (40)
TCl 1 (80)
I (80)
and without changing t h e V FO or P R ESELECTOR
settings, tune the RF signal gen erator to 3 .5 0 0
K H z
a n d obtain a 1 .000
Hz
beat note. A dj u st TCll
for maximum audio output as described i n step
2.
( 13 )
Repeat step 9. 10.
1
1 . and 12 to peak out the coil
adj u stmen t s for 80 meter bands.
( 14 )
Set the B A N D sw itch to 4 0 . V FO at 7 .000
K Hz
and the PR ESELECTOR to the low er edge of the
4 0 meter segment. Adjust TC2 and TC7 for maxi
mum transmitter power output into the dummy
load.
( 15 )Set the
VFO
at 7. 1 5 0
K Hz
and
PRESELECTOR
for
m aximum power output. Adj ust
L3 3
for maximum
power output into the dummy load.
( 16)Set the
OPERATION
sw itch to the receive mode, and
set the
VFO
or
PRESELECTOR
settings to the same
position as step 14 , tune the
RF
signal generator to
7,000
K Hz
and obtain a 1,000
Hz
beat note. Adj ust
TC12 for max imum audio output.
(17)
Set the BAND switch to 160.
V
F
O
at 1 .900
K Hz
and
the PRESELECTOR at 2 of the inner scale. Adj ust
TC28 and TClO for maximu m power output into
the dummy load.
(18) Turn the OPERATION sw i tch to the receive mode.
and leave the VFO and PRESELECTOR settings
unchanged. Apply the R F signal generator output
at 1 .900
K Hz
to antenna terminal. Adj ust TC2 9 for
max imum S-meter reading.
M AX .
C A P .
M I N .
CAP.
--
2 7 --