— 27 —
Table 1. Setting NMEA 2000 messages for the Barometer and Thermometer
Messages
setting
Description
0 (factory
setting)
Maximum compatibility mode. Transfer of the measured value
with instance data instance 0 in the following messages (PGN):
• Barometer: 130310, 130311, 130314;
• Thermometer: 130310, 130311, 130312, 130316.
1
Transfer of the measured value only in PGN 130310 message.
2
Transfer of the measured value only in PGN 130311 messages.
3..15
Transfer of the measured value only in PGN 130314 (Barometer)
and PGNs 130312 and 130316 (Thermometer) messages with data
instance 0..12.
We recommend using the maximum compatibility mode (value 0 in Table 1)
and not changing the factory settings of messages unnecessarily. If you change
the message setting to the value of 1 (see Table 1) and allow only PGN 130310 when
the Thermometer is configured to send measured data as engine room temperature
(see Table 2 in Section III), the Thermometer will stop transmitting temperature
data as engine room temperature cannot be sent in this message. When configuring
messages setting with the value of 0 and data type with the value of 13 (Freezer
temperature, see Table 2 in Section III), only messages with PGNs 130312 and 130316
will be transmitted, because these data cannot be transferred in other messages.
Regardless of settings, the Device receives and transmits NMEA 2000 service
messages (see Appendix C) and is displayed in the list of NMEA 2000 devices
(SeaTalk NG, SimNet, Furuno CAN).
Содержание YDBC-05
Страница 36: ...36 Figure 2 Digital sensor of the Thermometer...
Страница 40: ......