30

S P E C I F I C A T I o N S

These specifications represent typical performance and are subject to 
change without notice.  For the latest product specification information, 
please visit YSI’s website at ysi.com or contact YSI Tech Support. 

Parameter

Range

Resolution

Accuracy

Temperature

-5 to 55°C

0.1°C

± 0.2°C

pH

0 to 14 
pH units

0.01 

Instrument with cable 
and sensor: +/- 0.2

ORP

-1500 to
1500 mV

1 mV

Instrument with cable 
and sensor: +/-20 mV

Conductivity

0-500 uS/cm
0-5 mS/cm
0-50 mS/cm
0-200 mS/
cm (auto
ranging)

0.0001 to 
0.1 mS/cm; 
0.1 to 0 uS/
cm (range 
dependent)

Instrument only:  ± 0.5% 
of the reading or 1 uS/
cm, whichever is greater. 
Instrument with 1 or 
4 meter cables:
± 1.0% of the reading 
or 1 uS/cm, whichever 
is greater.
Instrument with 10, 20, 
or 30 meter cables:
± 2.0% of the reading 
or 1 uS/cm, whichever 
is greater.

Salinity

0 to 70 ppt

0.1 ppt

± 1.0% of the reading 
or ± 0.1 ppt, whichever 
is greater.

Total 

Dissolved 

Solids (TDS)

0 to 100 g/L. 
TDS Constant 
range: 0.3 
to 1.00 (0.65 
default)

0.0001 to 0.1 
g/L (range 
dependent)

Dependent on accuracy of 
temperature, conductivity 
and TDS Constant.

Содержание YSI Pro1030

Страница 1: ...USER MANUAL English Pro1030...

Страница 2: ...First Power On 7 System Setup Menu 7 Audio 8 Contrast 8 Temperature Units 8 ISE Sensor Type 9 ISE Units 9 Auto Stable 9 pH Buffer Set 10 Conductivity Units Cond Units 10 Specific Conductance Reference...

Страница 3: ...red by this warranty To exercise this warranty call your local YSI representative or contact YSI Customer Service in Yellow Springs Ohio at 1 937 767 7241 800 897 4151 or visit www YSI com for a Produ...

Страница 4: ...pack the instrument and accessories and inspect for damage Compare received parts with items on the packing list If any parts or materials are damaged or missing contact YSI Customer Service at 800 89...

Страница 5: ...u from the Run screen 2 Up Arrow Use to navigate through menus to navigate through box options along the bottom of the Run screen and to increase numerical inputs 3 Power and Backlight Press once to t...

Страница 6: ...y 1 o ring visible Failure to properly seat the sensor may result in damage 6 Twist the sensor clockwise to engage the threads and finger tighten Do NOT use a tool This connection is water tight The I...

Страница 7: ...System Setup menu the up and down arrow keys will move the highlighted bar up and down the system setup options See the System Setup menu section of this manual for more information about these option...

Страница 8: ...ther pH model 1001 or ORP model 1002 Use the up or down arrow keys to highlight ISE Sensor Type then press enter to open a submenu Highlight the sensor type corresponding to the sensor installed on th...

Страница 9: ...enter to enable or disable it An enabled conductivity unit will have an X in the box next to it Highlight the ESC Exit box along the bottom of the display and press enter to save any changes and to cl...

Страница 10: ...e a multiplier for the water at your sampling site Use the following procedure to determine the multiplier for a specific sample 1 Determine the specific conductance of a water sample from the site 2...

Страница 11: ...e and 10 seconds pH Buffer Set USA Conductivity Units cond mS cm and spc mS cm Parameter Reset Defaults Conductivity Auto Stable Off 0 0 Change and 10 seconds SPC Reference Temperature 25 C SPC Temper...

Страница 12: ...hold Cal for three seconds 3 Highlight pH and press enter If pH is not listed as an option check the System Setup menu to ensure pH is enabled in the ISE Sensor Type menu 4 Highlight 3 point and pres...

Страница 13: ...hloride when calibrating Specific Conductance since these solutions typically have a Temperature Coefficient of 1 91 C Additionally be sure to enter the value of the solution as it is listed for 25 C...

Страница 14: ...ess the Cal key to exit the calibration error message and return to the Run screen See the Troubleshooting section of this manual for possible solutions Taking M easurements Before taking measurements...

Страница 15: ...the data set number 01 through 50 Erasing Data While viewing saved data press the enter key to access the function boxes at the bottom of the display Next use the up or down arrow keys to highlight E...

Страница 16: ...prevent water from entering the port Once the ISE sensor is removed examine the connector inside the port If any moisture is present use compressed air to completely dry the connector or let it air d...

Страница 17: ...h all parts of the sensor tip without stress You can also use a pipe cleaner for this operation if more convenient i Dry the port and sensor connector with compressed air and apply a very thin coat of...

Страница 18: ...displays Calibration Over Calibration Under or Unstable Reading during calibration 1 Ensure the conductivity sensor is clean Follow the cleaning procedures in the Care Maintenance and Storage section...

Страница 19: ...uctivity 0 500 uS cm 0 5 mS cm 0 50 mS cm 0 200 mS cm auto ranging 0 0001 to 0 1 mS cm 0 1 to 0 uS cm range dependent Instrument only 0 5 of the reading or 1 uS cm whichever is greater Instrument with...

Отзывы: