With the LabStation, which is available as an accessory, you can con-
veniently use your pHotoFlex in the laboratory. 
Laboratory operation with the LabStation enables the following addi-
tional functions:

With photometric measurements, the zero measurement is retained 
even after switching the pHotoFlex off and on again

You can connect a bar code reader for the simplified calling up of 
programs

The LSdata software included serves to easily enter user-defined 
programs

Operation with power pack and rechargeable battery (included in the 
scope of delivery of the LabStation). The rechargeable battery in the 
pHotoFlex is automatically charged as soon as the meter is placed 
in the LabStation.

Fig. 1-1

LabStation

LabStation

LS Flex 430

Содержание WTW LabStation LS Flex/430

Страница 1: ...OPERATING MANUAL ba75968d02 11 2018 LS Flex 430 LabStation...

Страница 2: ...ba75968d02 11 2018 LS Flex 430 Copyright 2018 Xylem Analytics Germany GmbH Printed in Germany...

Страница 3: ...LS Flex 430 Contents 3 ba75968e02 11 2018 Contents Overview 4 Battery operation with LS Flex 430 5 Technical data 8...

Страница 4: ...o measurement is retained even after switching the pHotoFlex off and on again You can connect a bar code reader for the simplified calling up of programs The LSdata software included serves to easily...

Страница 5: ...hile the meter is switched off Charging time of the rechargeable battery approx 36 hours CAUTION Use original power packs only The line voltage at the operating site must lie within the input volt age...

Страница 6: ...screws 1 on the underside of the meter Remove the lid of the battery compartment 2 2 If necessary take four old batteries out of the battery compart ment 3 Connect the cable of the rechargeable batte...

Страница 7: ...ar code reader see operating manual of your pHotoFlex The baud rate of the bar code reader is given in the operating manual of the bar code reader 4 Connect the power pack to an easily accessible powe...

Страница 8: ...ined in the scope of de livery Euro US UK and Australian Serial interface Connection of the null modem cable included in the scope of delivery Baud rate Adjustable 1200 2400 4800 9600 19200 Baud Type...

Страница 9: ......

Страница 10: ...buildings factories and farms In more than 150 countries we have strong long standing relationships with customers who know us for our powerful combination of leading product brands and applications...

Отзывы: