6. Metrological data

Nominal width

DN

40

50

65

80

100

Q

s

Max. peak flow rate

m³/h

78

90

125

200

310

Q

4

Max. flow rate according to MID

m³/h

50

50

78.75

125

200

Q

3

Permanent load according to MID

m³/h

40

40

63

100

160

Q

2

Cut off according to MID

m³/h

0.06

0.06

0.1

0.16

0.25

Q

1

Minimum flow rate according to MID

m³/h

0.04

0.04

0.06

0.1

0.16

Q

3

/Q

1

Max. ratio

1000

1000

1000

1000

1000

Starting flow

m³/h

0.012

0.012

0.02

0.033

0.054

∆p

Pressure loss at Q

3

bar

0.15

7. Marking

8.Installation

8.1. Hazard warnings

The meter must be installed without mechanical stress in the pipe. A mechanically stressed installation may lead to the destruction of the meter 
housing. This would cause water to escape.
The pipe pressure must not be higher than the pressure specified on the rating plate. Excessive pressure can lead to leakages or destruction of 
the meter housing. This would cause water to escape.

8.2. General information

The Cordonel meter may only be installed by a qualified and instructed specialist. The generally accepted rules of technology and the applicable 
safety regulations must be observed at all times (in particular, the notes contained in standard ISO 4064-5:2014).

The meters are disinfected after the production process. Handling during installation must be carried out in accordance with applicable hygiene 
rules. We refer in particular to VDI/DVGW Guideline 6023 Section 6.7 and 6.8 and DVGW Worksheet W557 Section 5. Before installing the me-
ter, it must be disinfected again. We recommend removing the meter from the transport packaging at the actual measuring point shortly before 
installation.

Install the meter in such a way that no forces greater than 100 kg can act on any of the plastic parts.

8.3. Required tools

Two wrenches or hexagon socket wrenches, both corresponding to the nominal size of the bolts used. In some cases, suitable lifting gear.
The variable parameters are programmed by radio using the Sensus SIRT radio interface and the Diavaso config app from Sensus.
 

8.4. Installation positions

The meter can be installed in horizontal and vertical pipes. It should be installed in such a way that the LCD is easy to read.

Do not install the meter with the display facing downwards or with the display upside down.

4

4

8

Cordonel

Page 4

Radio frequency

Battery life

Manufacturer's address

Name

Radio address

Disposal symbol

Data matrix code

Nominal width
Nominal flow, ratio
Max. temperature
Nominal pressure

Low profile class

Conformity mark
Approval number

Serial number
Country of origin

Содержание Sensus Cordonel DN 100

Страница 1: ...Cordonel Static Flow Meter Installation and Operating Instructions...

Страница 2: ...Commissioning 5 8 7 Operation notes 5 9 Reading 5 9 1 Display description 5 9 2 Display sequence 6 9 3 Alarms 6 9 4 Testing mode 7 10 Data logger 7 11 Radio 8 11 1 General 8 11 2 SensusRF 8 11 3 wM Bu...

Страница 3: ...receive ultrasonic signals with and against the direction of flow of the water The time the signal takes to go from the transmitter to the receiver is measured The flow velocity is calculated using th...

Страница 4: ...O 4064 5 2014 The meters are disinfected after the production process Handling during installation must be carried out in accordance with applicable hygiene rules We refer in particular to VDI DVGW Gu...

Страница 5: ...iring in the direction of flow upstream of the meter Use suitable measures to protect the meter against water hammers in the pipe Do not carry out welding work on the pipe with the meter installed to...

Страница 6: ...rm flag and alarm code Alarm Code Description Comment ALr 001 Low battery alarm Appears when the remaining battery life is approx six months ALr 004 Empty pipe alarm Appears when the measuring pipe is...

Страница 7: ...adio command The testing mode is terminated automatically after 72 hours at the latest The time of the automatic termination of the testing mode can be set using the Diavaso config app Switching to te...

Страница 8: ...5 seconds After every fourth BUP the meter listens for a short period LAT as to whether further information is requested If a radio com mand PAM is received during this period the meter sends the corr...

Страница 9: ...saved meter reading Volume unit Time that data was last saved 13 Factory settings Values Unit DN 40 DN 50 DN 65 DN 80 DN 100 Leakage duration Days 14 Leakage threshold value m h 0 25 0 375 0 625 0 875...

Страница 10: ...e Off Key date value net volume On Key date value alarm status On Wake up interval Sec 3 UTC time shift Hours 0 Pulse On Pulse mode A4 balanced pulse Pulse value Litres 100 Pulse length ms 500 1 The i...

Страница 11: ...bserve section 8 2 18 Transportation The meters should be transported dry as frost free as possible and under hygienically harmless conditions If possible the meters should always be transported in th...

Страница 12: ...ity Cordonel Page 12 Sensus GmbH Hannover Meineckestra e 10 30880 Laatzen T 49 0 5102 74 0 F 49 0 5102 74 3341 Email info int xylem com www sensus com MB 2000 INT Version 0004 May 2021 Subject to chan...

Отзывы: