11
On 12 volt pump:
Minimum voltage of 10.5 volts required.
On 24 volt pump:
Minimum voltage of 21 volts required.
CAUTION:
Disconnect power from the
system before working on the unit to avoid
personal injury, damage to the surrounding
environment and/or damage to the unit.
CAUTION:
Always install proper fuse size to
prevent damage to product should a short occur.
Failure to install proper fuse could increase risk
of pump malfunction potentially resulting in
personal injury and/or fire hazard.
CAUTION:
Keep all wire connections
above the highest water level. Wires must be
joined with butt connectors and a marine grade
sealant to prevent wire corrosion.
WARNING:
Electrical connections
should be performed by a competent marine
electrical technician.
CAUTION:
Connecting brown or brown/white wires to negative battery terminals will result in
pump failure. Install all brown wires to positive terminal only and black to negative terminal only.