en
– Original instructions
12
1.
Series
SMB
2.
Number of pump units
[10] = 1 pump unit
[20] = 2 pump units
[30] = 3 pump units
3.
Non-return valve
[_] = Delivery side
[RA] = Suction side
4.
Certificate of drinking water
unit
A = WRAS, ACS, M.D.174
B = ACS, M.D.174
Z = not certified by a third party
5.
e-SM pump unit
SVE
VME
HME
6.
Control panel power supply [M2] = Single-phase, 1 x 230 V
[T3] = Three-phase, 3 x 230 V
[T4] = Three-phase, 3 x 400 V
7.
Version of material
[__] = Standard component
[A304] = Special AISI 304 version
[B304] = Special AISI 304 version
[C304] = Special AISI 304 version
[A316] = Special AISI 316 version
[B316] = Special AISI 316 version
[C316] = Special AISI 316 version
8.
Option
[PA] = Minimum pressure pressure switch on the suction manifold, for protection
against dry running.
[WM] = Wall-mounted control panel; cables L= 5 m
NOTE: Refer to the B/W catalogue for further details
3.2.2 Distribution panel
Data plate of the control panel
Figure 4: Data plate of the control panel
1.
Control panel definition code
2.
Code of the control panel
3.
Rated voltage
4.
Rated current
5.
Serial number (date+progressive number)
6.
Protection grade
7.
Rated frequency
8.
Short circuit current