Therefore, the direction of rotation of three-phase pumps 
must always be checked if the cable between pump and 
controller has been removed. 
 

Green LED „Operation“ 

The green LED illuminates when the pump is operating. 

Red LED „Alarm“ and „Failure“ 
- Permanent Signal 

The red Alarm-LED illuminates in case of to high liquid level 
in tank. Together with the red LED, the built-in acoustic 
alarm is activated if the switch in the front cover is in posi-
tion „On“. Furthermore, the external fault signal device, if 
fitted, is activated. 
If the red Alarm-LED illuminates together with the green 
LED, the pump operates, but the liquid level in the tank is 
above the alarm level. The alarm is automatically reset 
when the liquid level has been lowered below the alarm 
level. 
If the red LED illuminates together with the LED „Failure“, 
the pump was stopped by thermal cutout. In this case, push 
the „Reset“ switch. If the pump still does not work, please 
contact your 

XYLEM

 service. 

 
Red LED „Failure“ 
- Flash Signal 

The Failure-LED flashes when the annual maintenance is 
recommended after 2 months. 
 

Deactivating of „Maintenance flash“:  

Set the operation switch in position „Aus/Off“, then press 
th

e „Reset“-button. After releasing „Reset“ the LED „Alarm“ 

lights up for approx. 1 second. Within this time set the op-
eration switch in position „Auto“. The flash light extinguish. 
 

Reactivating of „Maintenance flash“ (only possible by 
using ServCom Service-Controller):  

Reset the maintenance counter in the ServCom menu. 
Subsequently set the operation switch in position „Aus/Off“, 
then press the „Reset“-button. 

 
Note:  

Deactivating „Maintenance flash“ is possible starting from 
version 1.0d of the pump control (see menu in ServCom). 
„Maintenance flash“ is deactivated, if „!“ appears behind in 
ServCom the version No;  
„Maintenance flash“ is activated, if „!“ behind the version 
No. is missing. 
 

Red LED „Alarm“ 
- Flash Signal 

The Alarm-LED flashes when the control unit has monitored 
several pump operation circuits longer than 2 minutes 
each. Please contact your 

XYLEM

 service. 

 

5.2.2. Twin station

 

The function selector offers the following functions: 
 

Operation switch (one per pump) 

Position „Manu“ 

The pump operates, irrespective of the liquid in the tank. 

Position „Off“ 

The pump is stopped. 

Position „Auto“ 

Automatic pump operation according to the liquid level in 
the tank.  
 

Acoustic alarm switch   

Position „On“ 

The built-in acoustic alarm is activated. Together with the  
LEDs “Alarm“ and „Failure“, the built-in acoustic alarm will 
start if the liquid level is above the alarm level. The alarm is 
automatically reset when the liquid level has been lowered 
below the alarm level. 
 
 

Position „Off“ 

The built-in acoustic alarm is not activated. 
 
The controller front cover features 

Light-Emitting Diodes 

(LEDs)

 for indication of operating conditions: 

 

Green LED „Operation“ (one per pump) 

The green LED illuminates when the according pump is 
operating. 

 
Red LED „Failure“ 
- Permanent Signal 

The Failure-LED illuminates in case of a thermal cutout of a 
pump. Together with the Failure-LED, the Alarm LED illu-
minates and the built-in acoustic alarm is activated if the 
switch in the front cover is in position „On“. Furthermore, 
the external fault signal device, if fitted, is activated. Auto-
matically the unit turns over to operation of the second 
pump. 
In this case push the „reset“ switch. If the Failure-LED still 
does not extinguish please contact your 

XYLEM

 service. 

 

Red LED „Failure Pump 1“ 
- Flash Signal 

The Failure-LED flashes when the annual maintenance is 
recommended after 2 months. 
 

Deactivating of „Maintenance flash“:  

Set the operation switch pump 1 in position „Aus/Off“, then 
press the „Reset“-button. After releasing „Reset“ the LED 
„Alarm“ lights up for approx. 1 second. Within this time set 
the operation switch pump 1 in position „Auto“. The flash 
light of „Failure Pump 2“ extinguish. 

 
Reactivating of „Maintenance flash“ (only possible by 
using ServCom Service-Controller):  

Reset the maintenance counter in the ServCom menu. 
Subsequently set the operation switch in position „Aus/Off“, 
then press the „Reset“-button. 
 

Note:  

Deactivating „Maintenance flash“ is possible starting from 
version 1.0d of the pump control (see menu in ServCom). 
„Maintenance flash“ is deactivated, if „!“ appears behind in 
ServCom the version No;  
„Maintenance flash“ is activated, if „!“ behind the version 
No. is missing. 
 

Red LED „Failure Pump 2“ 
- Flash Signal 

The Failure-LED flashes when the control unit has moni-
tored several pump operation circuits longer than 2 minutes 
each. Please contact your 

XYLEM

 service. 

 

Red LED „Alarm“ 
- Permanent Signal 

The red LED illuminates in case of to high liquid level in 
tank. Together with the red LED, the built-in acoustic alarm 
is activated if the switch in the front cover is in position 
„On“. Furthermore, the external fault signal device, if fitted, 
is activated. 
If the red LED illuminates together with the two green LEDs 
the pumps are operating, but the liquid level in the tank is 
above the alarm level. The alarm is automatically reset 

 

Содержание LOWARA SEKAMATIK 50E Series

Страница 1: ...Liste 5354 1 BA Dezember 2014 Montage und Bedienungs anleitung Installation and Operation Instruction Manual Baureihe Series SEKAMATIK 50E SEKAMATIK 50D...

Страница 2: ...le EC Declaration of Conformity valid only for XYLEM Service Austria GmbH aggregate supplied in is entirety according to EC Machinery Directive 2006 42 EC Appendix IIA Hersteller XYLEM Service Austria...

Страница 3: ...iche 6 3 Garantie 6 4 Transport und Lagerung 6 5 Elektroanschluss 6 5 1 Allgemeines 6 5 2 Elektronik Steuerger te 6 5 3 Phasenvertauschung 7 6 Montage und Installation 8 7 Inbetriebnahme 9 8 Wartung u...

Страница 4: ...ger Spalt und Schlei ringe usw weiters durch Transport oder unsachgem e Lage rung verursachte Sch den Voraussetzung f r die Gew hr leistung ist dass die Pumpe bzw das Aggregat gem der am Typenschild d...

Страница 5: ...ieren dem Edelstahl Schneidkopf und zerkleinert mitgef hrte Feststoffe so dass das F rdermedium durch geringe Rohr leitungsquerschnitte ab DN 50 gepumpt werden kann Die Hebeanlagen sind mit einer pneu...

Страница 6: ...chtigkeit gesch tzt sind Netzanschlusskabel und Ste cker sind vor Gebrauch auf Besch digung zu pr fen Das Ende des Anschlusskabels darf nicht ins Wasser eingetaucht werden da sonst Wasser in den Motor...

Страница 7: ...ch Wartungsblinken ist deaktiviert wenn im ServCom hinter der Versions Nr ein erscheint Wartungsblinken ist aktiviert wenn hinter der Versions Nr das fehlt Rote LED Alarm Dauersignal Leuchtet wenn der...

Страница 8: ...nseren Kundendienst XYLEM ServCom Contoller zum Programmieren und Abru fen von Betriebsdaten als Zubeh r erh ltlich 5 3 Phasenvertauschung Bei 1Ph Motoren ist eine Kontrolle der Phasenfolge nicht notw...

Страница 9: ...inschalten des Membrandruckschalters der Steuerautomatik erforderliche Niveau erreicht hat Erreicht der Pegel das Ausschaltni veau schaltet die Pumpe ab 8 Wartung und Reparatur Bei einem eventuellen D...

Страница 10: ...ausgleichs schlauch undicht o der verstopft Schlauch berpr fen und ggf er neuern oder reini gen Sicherung im Schalt ger t defekt Sicherungen ber pr fen Pumpe schaltet nicht ab Druckausgleichs schlauch...

Страница 11: ...3 Warranty 14 4 Transport and Storage 14 5 Electrical Connection 14 5 1 General instructions 14 5 2 Electronic control box 14 5 3 Check of Direction of Rotation 16 6 Installation 16 7 Start Up 16 8 Ma...

Страница 12: ...improper storage are not covered by the guarantee In order for the guaran tee to apply it is essential that the pump or pump unit is used in accordance with the operating conditions given on the type...

Страница 13: ...50 D are equipped with a cutter system at the pump inlet which cuts all soft solids to small particles so that the liquid may be pumped through small diameter discharge pipes of 50mm The controllers i...

Страница 14: ...ion of the pump should be carried out in accordance with local requirements The operating voltage and frequency are marked on the pump and controller nameplates Voltage tolerance 6 up to 10 of the vol...

Страница 15: ...activated Together with the LEDs Alarm and Failure the built in acoustic alarm will start if the liquid level is above the alarm level The alarm is automatically reset when the liquid level has been...

Страница 16: ...ming sewer inlet which correspond to the diameter of the inlet The diameter of the discharge pipe must be DN 50 SEKAMATIK 50 E and SEKAMATIK 50 D and should not installed in close arcs The discharge p...

Страница 17: ...screw and infer a small quantity of oil The oil becomes greyish white like milk if it contains water This may be the result of defective shaft seal In this case leave the condition of the shaft seals...

Страница 18: ...h he 250mm Direct connection hanging WC inlet height 250mm 12 Bauma e Dimensions SEKAMATIK 50 E A Zulauf horizontal DN 100 Horizontal inlet DN 100 B Anschluss f r pneumatische Steuerung Connection for...

Страница 19: ...llowing list contains parts that do not correspond to every pump type For spare part or ders please always give Pump type The year of construction see the pump label Position number xx take the exact...

Страница 20: ...13 2 Ersatzteilzeichnung Sammelbeh lter Spare part drawings collecting tank SEKAMATIK 50 E SEKAMATIK 50 D...

Страница 21: ...cheibe 932 Sicherungsring 940 Passfeder 950 Ausgleichsscheibe 970 Typenschild 990 xx Motor l 13 3 Spare part list for submersible pump ATTENTION The following list contains parts that do not correspon...

Страница 22: ...22 13 4 Ersatzteilzeichnung Pumpe Spare part drawings pump SEKAMATIK 50 E 15M 13T SEKAMATIK 50 D 15M 13T SEKAMATIK 50E 25T SEKAMATIK 50D 25T...

Страница 23: ...Nr Bezeichnung Menge Lieferanschrift Unterschrift Firmenstempel 14 Order Sheet for Spare Parts To XYLEM Water Solutions Austria GmbH A 2000 Stockerau Ernst Vogel Strasse 2 Fax 0043 2266 65311 Pump ty...

Страница 24: ...se 2 2000 Stockerau sterreich Telefon 43 0 2266 604 Telefax 43 0 2266 65311 e mail info austria xyleminc com web www xylemaustria com nderungen auch ohne vorherige Ank ndigung sind Xylem Water Solutio...

Отзывы: