en - Original instructions
e-SV series - Installation, Operation and Maintenance Manual
11
3
Technical Description
3.1
Designation
Multistage vertical centrifugal pump unit, non-self-priming.
The product may be supplied as full pump unit (pump and motor), or as pump only.
3.2
Data plate
The data plate is a label showing:
The main unit details
Identification code.
Figure 5: Data plate
Position
number
Description
Position
number
Description
1
Pump or pump unit type
8
Flow rate range
2
Pump or pump unit code
9
Head range
3
Mechanical seal materials
identification code
10
Speed
4
O-ring material identification code
11
Rated or maximum power
5
Maximum operating pressure
12
Minimum efficiency index (MEI) (EU
Regulation no. 547/2012)
6
Maximum liquid operating
temperature
13
Serial manufacturing date
7
Minimum liquid operating temperature 14
Weight