background image

ELECTRICAL  CONNECTIONS  -  Select  a  location  for

the switch and instruction plate, making sure wire leads

from both the toilet and power source can be routed to

the switch. Ensure the panel where installing switch is no

more than 1" thick. Drill a 5/8" mounting hole and install

switch and instruction plate. Use stranded copper wire of

the correct size (determined from the electrical specifi-

cations chart) to connect one side of the switch to the

positive power source. An appropriate size fuse or equiv-

alent circuit breaker (determined from electrical specifi-

cations  chart)  must  be  installed  in  the  positive  power

lead within seven inches of the power source. Connect

the other side of the switch to the orange (positive) motor

lead.  Connect  the  black  (negative)  motor  lead  to  the

negative side of the battery or grounded buss bar.
NOTICE:  Correct  motor  polarity  (orange  to  positive,

black  to  negative)  is  important.  Reverse  polarity  can

damage  motor  and  void  warranty.  Full  voltage  at  the

motor is required to properly operate the Electric Toilet.

The toilet must be wired in a circuit independent of all

other accessories.

ELECTRICAL SPECIFICATIONS

AMP

FUSE

WIRE SIZE PER FEET OF RUN*

VOLTAGE

DRAW

SIZE

0'-10'

10'-15'

15'-25'

25'-40'

40'-

60'

12 Vdc 

16

25

#12

#10

#10

#8

#6

24 Vdc

8

15

#16

#14

#12

#10

#10

* Length of run is total distance from power source to product and back to ground.

OPERATING INSTRUCTIONS

Make sure inlet and outlet seacocks are all open; push button

to  operate.  Operate  until  bowl  is  completely  flushed  and

discharge pump has scavenged water from bottom of bowl.
The Jabsco electric marine toilet will provide years of trou-

blefree service if properly used. It will handle waste and toi-

let tissue. It will NOT handle rags, sanitary napkins or hard

solid objects.
If bowl does not pump out and begins to fill, partially close

inlet  valve  until  bowl  is  cleared  and  completely  pumped

out. Then operate for a few seconds with both valves open

to clear entire toilet and discharge system. For maximum

safety, when toilet is not in use or vessel is unattended,

close both the inlet and discharge seacocks.
To drain for winter lay-up, close inlet valve and operate for

a few seconds until all water is pumped out.
After long periods of non-use, toilet and pump may dry out.

To ease initial start-up, put about one quart of water in bowl

and let stand awhile before initial use.

DISASSEMBLY

Disconnect pumping inlet and discharge hoses. Remove

four screws, Key No. 25, pull out com plete motor, pump

and macerator assembly. If assembly does not slide out

easily, push forward and pull back sharply several times to

free macerator housing from base.
Remove  discharge  port,  Key  No.  12,  and  joker  valve.

Unscrew chopper plate, Key No. 14, by turning counter -

clock wise, facing plate. Prevent shaft from turning by plac-

ing  screwdriver  in  discharge  port  and  locking  centrifugal

impeller  blade.  Remove  macerator  housing.  Loosen

impeller set screw and slide impeller off motor shaft.
Remove four flathead screws and two washers, Key Nos.

20, 21, & 22. Remove the plastic wear plate, Key No. 23,

with sealing sleeve, Key No. 19, and gasket, Key No. 26.

Slide pump assembly off motor shaft. Replace all worn or

damaged parts, clean remaining parts.

ASSEMBLY

Press seal into body with lip facing impeller; be careful

not to cock seal in bore. Install pump body on motor and

position on register. Lubricate impeller bore with pump

grease and install impeller. Position the gasket against

the body and install the wearplate ensuring the two plas-

tic sealing washers are under the heads of the top and

bottom  screws.  NOTE:  The  current  plastic  wearplate

supercedes  the  earlier  brass  wearplate  and  with  it  the

stainless  steel  wearplate  is  no  longer  used.  Slide  the

rubber sealing sleeve on the motor shaft and push it into

its recess in the wearplate. Relocate centrifugal impeller

on shaft, about 1/8" from the wearplate, and tighten set

screw. Place macerator housing over shaft and centrifu-

gal impeller, put lock washer on end of shaft and screw

chopper plate on shaft and tighten. Install O-ring in O-

ring groove in wearplate surface, a little grease will help

hold in place, make sure inside body surfaces are clean,

line up slot in base with key on macerator housing, slide

pump  assembly  into  base  and  tighten  with  the  four

screws. Turn motor on for one or two seconds to be sure

c e n t r i f u g a l

impeller  is

free.

WARNING

!

Flood hazard.  Close inlet and outlet 

seacocks prior to disassembling toilet.  

Failure to do so can result in flooding 

which can cause loss of property and life.

MOUNTING 

 BRACKET 

VENT TO 

 

ATMOSPHERE 

ELECTRICAL 

 

CONNECTIONS 

TO VENTED 

  LOOP 

 

 

 

 

VIEW A 

37068-0000

SOLENOID

 

 

TO 

 

NEGATIVE 

TO 

 

POSITIVE 

TO 

 

NEGATIVE 

PUSH BUTTON 

 

SWITCH 

VENTED 

  LOOP 

VIEW A 

DISCHARGE TO 

 HOLDING TANK 

INLET 

WATER 

  LINE 

 

Отзывы: