Model 

18620-0003

REVERSIBLE PUMP

FEATURES

Body:

Bronze

Impeller: 

Nitrile

Seal:

Lip Type

Motor:

Reversible Permanent Magnet Type with

Integral Reversing Switch and Fuse

Ports:

3/4" Garden Hose External

Height:

3-3/8" (85mm)

Length:

8-5/8" (172mm)

Width:

4" (95mm)

Weight:

5-1/2 lb (2.5 kg) Approx.

APPLICATION

Use  for  circulating  and  draining  bait  tank,  engine  oil

changing or general pumping requirements. With a wet

impeller, pump will produce a suction lift of about 3 to 4

feet (0.9 to 1.2m) and a lift of about 10 feet (3m) when

primed. 

BE SURE SUCTION LINES ARE AIRTIGHT.

INSTALLATION

The  pump  must  be  mounted  in  a  dry  location  -  the 

motor  is  not  waterproof  and  must  not  be  submerged.

SELECTION  OF  A  COOL,  VENTILATED location  will

generally  extend  pump  motor  life.  The  unit  can  be

mounted in any desired position. It is best to mount so

that  water  dripping  from  loose  port  connection  will  not

wet  the  motor.  The  pump  head  may  be  mounted  at 

90  degree  increments  on  the  motor  to  accommodate

plumbing connections as needed.

PLUMBING CONNECTIONS

Pumps have external hose threads and internal 3/8" pipe

threads.  Use  hose  that  does  not  kink  when  bent  or

 collapse due to the suction of the pump. Arrange hoses

to trap liquid in pump body to wet the impeller. Wetting

the impeller aids in priming and extends impeller life. All

hoses must have airtight connections.

HEAD VS. FLOW TABLE

Total Head

Capacity

PSI

Feet

Metres

GPM

LPM

2.1

5

1.5

1.8

6.8

4.3

10

3.0

1.7

6.4

8.7

20

6.1

1.6

6.1

17.4

40

12.2

1.2

4.5

Table shows approximate Head-Flow for new pump.

WARNING

!

Explosion hazard.  Do not pump gasoline, solvents, 

thinners or other flammable liquids.  To do so can 

cause an explosion resulting in injury or death.

Explosion hazard.  Do not operate with rivets 

removed from motor case.  Explosion resulting in 

personal injury, death or property damage can 

occur.  Case openings must be sealed to avoid 

explosion and maintain ignition protected rating.

WARNING

!

MODEL 18620-0003

Содержание Jabsco 18620-0003

Страница 1: ...ll not wet the motor The pump head may be mounted at 90 degree increments on the motor to accommodate plumbing connections as needed PLUMBING CONNECTIONS Pumps have external hose threads and internal 3 8 pipe threads Use hose that does not kink when bent or collapse due to the suction of the pump Arrange hoses to trap liquid in pump body to wet the impeller Wetting the impeller aids in priming and...

Страница 2: ... 10 21 30 ft 9m 10 NOTICE To prevent motor damage use only multi strand copper wire in size recommended DO NOT use ordinary lamp cord or other substitutes OPERATION Flexible impeller pumps must NOT be run dry as the pumped liquid is the lubricant for the impeller Observe the outlet and shut off pump as soon as liquid stops flowing The pump cannot run against a closed outlet such as encountered whe...

Страница 3: ... 5 With a 1 2 diameter dowel push agains the shaft seal from back motor side of the body to dislodge it from the seal bore NOTE Do not tamper with or disassemble motor ASSEMBLY 1 Lubricate seal with water and position it in seal bore with lip or hollowed out side of seal pointing towards the impeller bore With a 1 2 diameter dowel push against the shaft seal into its bore until it contacts the bot...

Страница 4: ...warranty does not extend to or apply to any unit which has been repaired or altered at any place other than Jabsco s factory or by persons not expressly approved by Jabsco nor to any unit the serial number model number or identification of which has been removed defaced or changed 6 Components manufactured by any supplier other than Jabsco shall bear only that warranty made by the manufacturer of ...