Figure 4
Optional B&G Flange Supports can be used when rigid pump support to the floor or
isolation base is required. The supports are installed on the back side of the pump flanges
and have tapped holes to accept the flange bolting and have mounting holes in their
bases for anchor bolts. Pipe supports (not shown) are required such that the pump flanges
are not supporting the piping.
Figure 5
Alternately with the optional B&G Flange Supports, insolation pads can be used between
the support and the floor.
Figure 6
Pumps with motors 256 NEMA frame and below can be installed with the shaft horizontal
and the piping vertical with supports for the piping (not shown) adequate to carry the
loads from the pump and piping.
Figure 7
Pumps with motors 256 NEMA frame and below can also be installed with the shaft
horizontal and the piping horizontal with supports for the piping (not shown) adequate to
carry the loads from the pump.
4 Installation
14
Marlow Series e-580 INSTRUCTION MANUAL
Содержание Goulds Marlow e-580 Series
Страница 1: ...INSTRUCTION MANUAL P2002885 Rev B Marlow Series e 580 ...
Страница 2: ......
Страница 30: ......