2.3 Storage guidelines
Storage location
NOTICE:
• Protect the product against humidity, dirt, heat sources, and me-
chanical damage.
• The product must be stored at an ambient temperature from
-40°C to +60°C (-40°F to 140°F).
3 Product Description
3.1 Pump design
The pump is a multistage, non-self priming pump. The pump can be
used to pump:
• Cold water
• Warm water
Intended use
The pump is suitable for:
• Civil and industrial water distribution systems
• Irrigation (for example, agriculture and sporting facilities)
Improper use
DANGER:
Do not use this pump to handle flammable and/or explosive
liquids.
An improper use of the product leads to the loss of the warranty.
3.2 Application limits
Table 1: Pressure and temperature limits
Seal Code 1HM, 3HM
5HM
10HM,
15HM,
22HM
2-6 Stages 7+ Stages 2-5 Stages 6+ Stages All Stages
BQE
147PSI at
248F
235PSI at
248F
147PSI at
248F
235PSI at
248F
235PSI at
248F
BQV
147PSI at
248F
235PSI at
248F
147PSI at
248F
235PSI at
248F
235PSI at
248F
QQE
147PSI at
248F
235PSI at
194F
147PSI at
248F
235PSI at
194F
235PSI at
194F
QQV
147PSI at
248F
235PSI at
194F
147PSI at
248F
235PSI at
194F
235PSI at
194F
BVE
147PSI at
194F
Not Avail-
able
147PSI at
194F
Not Avail-
able
Not Avail-
able
3.3 The data plate
The data plate is a label on the pump. The data plate lists key product
specifications.
1.
Goulds Water Technology Catalog Number
2.
Capacity range
3.
TDH range
4.
Rated speed
5.
Rated horsepower
6.
Maximum operating pressure
7.
Maximum fluid temperature
8.
Pump serial number
IMQ or other marks (for electric pump only)
Unless otherwise specified, for products with a mark of electrical-relat-
ed safety approval, the approval refers exclusively to the electrical
pump.
4 Installation
Precautions
WARNING:
• Observe accident prevention regulations in force.
• Use suitable equipment and protection.
• Always refer to the local and/or national regulations,
legislation, and codes in force regarding the selection of
the installation site, plumbing, and power connections.
4.1 Facility requirements
4.1.1 Pump location
DANGER:
Do not use this unit in environments that may contain flam-
mable/explosive or chemically aggressive gases or powders.
Guidelines
Observe the following guidelines regarding the location of the prod-
uct:
• Make sure that no obstructions hinder the normal flow of the cool-
ing air that is delivered by the motor fan.
• Make sure that the installation area is protected from any fluid
leaks, or flooding.
• If possible, place the pump slightly higher than the floor level.
• The ambient temperature must be between -30°C (-22°F) and
+40°C (+104°F) unless otherwise specified in the data plate.
• The relative humidity of the ambient air must be less than 50% at
+40°C (+104°F).
3 Product Description
Model e-HM Installation, Operation, and Maintenance Manual
3