WS011677A
2. Adjust the start sensor so that it is level with the lifting handle of the pump.
3. Install the alarm sensor half a meter higher than the start sensor.
NOTICE:
It is essential to ensure the proper functioning of level regulators in the unit.
Install the open bell
1. Read the open bell manual.
2. Put the open bell at the correct level. See the following figure.
1
2
3
4
5
6
7
8
9
10
WS007108A
1. Inlet pipe
2. Option: open bell, high water
3. Open bell, bottom level
4. Pump off
5. Pump on
6. Alarm off
7. Alarm on
8. Bottom level pipe sleeve
9. Inlet pipe by building contractor
10. Open bell, open system