2
BevJet 5000 Series Electric Bag-in Box Pump
WARNING:
This appliance can be used by children aged from 8 years and above and persons with reduced physical,
sensory or mental capabilities, or lack of experienceand knowledge, if they are been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the
appliance. Cleaning and user maintenance shall not be made by children without supervision.
Model Number
BIB5000A
BIB5002A
BIB5003A
BIB5004A
BIB5005A
Power adapter
US Plug
91006085
AU Plug
91006078
UK Plug
91006074
EU Plug
91006082
DC Cable no plug
20030706
Approvals
NSF, UL Listed
NSF, RCM
NSF, CE
NSF, CE
NSF, CE, RCM,
UL Recognized
Component
Electrical ratings
100-240 VAC 50/60 Hz 1.5 A
12 VDC 1.2 A
Shut Off pressure
40 PSI (2.7 BAR)
Liquid temperature
109ºF (43ºC) maximum
Pump design
Positive displacement
Wetted pump parts:
Housing
Elastometers
Check valve spring
Polypropylene
EPDM & TPV
Stainless Steel
Inlet port
3/8 (9.5 mm) port fitting
Outlet port
3/8 (9.5 mm) barb fitting
Net weight
2.3 lb (1.04 Kg.)
Dimensions
Length:
Width:
Height:
7.63” (19.38 cm)
5.12” (13.00 cm)
2.95” (7.5 cm)
The BIB5000 is only to be used with the power supply adapter
provided, and must be supplied at SELV.
Application
• Designed for dispensing wine, non pulp juice, teas or alcohol
<15% from Bag-in-Box
• Ideal for under counter installation
Special features
• Quick, simple, safe installation
• Compact size for easy mounting
• Sealed box unit with one piece molded
• Easily accessible manual on/off switch to restart the pump
• Self priming
• Able to run dry without damage
• Quiet operation
• Built in shut-off automatically turns pump off when bag is
empty and restarts when a full bag is connected
INSTALLATION
Installation procedure:
– See Figure 1
1.
Connect Vacuum switch to inlet port as shown. Be sure clip lock
switch in place.
2.
Plug barrel connector into receptacle marked “Switch” on the
main pump unit
3.
Connect suction hose to 3/8” barb on switch (secure with
clamp) and to BIB.
4.
Pump is 12VDC. The power adapter furnished with the unit
is to be plugged into the AC Voltage specified on the power
adapter.
5.
Activate the unit by turning the power switch on the control
box to the “ON” position.
6.
Regular cleaning and sanitizing of the Flojet pump is required.
Refer to Flojet document #81000457 for instructions on
cleaning and sanitizing the Flojet pump.
Typical beverage installation:
– See Figure 2
CAUTION:
Do not place BIB5000 into a dishwasher as it will cause electrical failure of pump and controls.
CAUTION:
The BIB5000 must be installed in an enclosure and/or protected from any splash or spillage.
CAUTION:
Not intended for outdoor use.