4.7  Change the position of the motor
housing

WARNING:

• Drain the system if possible or close the service valves on

both sides of the pump before disassembling the pump.

The pumped fluid can be pressurized and may be scald-

ing hot.

• There is the risk of escaping vapor when the motor is sep-

arated from the pump housing.

Electrical Hazard:

Before starting work on the unit, make sure that the unit and

the control panel are isolated from the power supply and

cannot be energized.

CAUTION:

Burn hazard. During operation various surfaces on the unit

will become hot. To avoid burn injury, use heat protective

gloves.

WARNING:

• A strong magnetic field is created when the rotor is re-

moved from or inserted into the motor housing. This mag-

netic field can be harmful to pacemaker wearers and oth-

ers with medical implants. In addition, the magnetic field

may attract metal parts to the rotor which can cause inju-

ries and/or damage the bearing of the pump.

3

2

4

6

5

1

Figure 2: Change the position of the pump head for 1 PH

4

6

5

3

1

2

Figure 3: Change the position of the pump head for 3 PH

1. Loosen the four hex-head screws (2) that fix the motor to the pump

housing (4) using the T-handle allen wrench described.

2. Rotate the motor (1) in 90° steps to the desired position.
3. In case of separation of the motor housing from the pump body (4):

a) avoid removing the rotating assembly from motor housing;

b) note the magnetic hazard listed above.
A defective O-ring must be replaced. A spare O-ring is already

available inside the package.

4. Properly align and tighten the four hex-head screws (2) that affix the

motor to the pump body (4) according to the torque table given be-

low in a criss cross pattern.

Nominal HP

Screw size

Torque

1/12 & 1/6

M6

90 in-lb

1/2

M8

170 in-lb

1 & 2

M10

340 in-lb

3

M10

340 in-lb

CAUTION:

Check for the presence of leaks after reassembling the

pump.

4.8  Electrical installation

Precautions

WARNING:

• Make sure that all connections are performed by a quali-

fied electrician in accordance with all applicable codes,

ordinances and good practices. Failure to follow these in-

structions could result in serious injury, death and/or

property damage.

• Before starting work on the unit, make sure that the unit

and the control panel are isolated from the power supply

and cannot be energized.

Grounding (earthing)

WARNING:

Reduced risk of electric shock during operation of this pump

requires the provision of acceptable grounding.

Be sure the following are adhered to. Failure to follow these instruc-

tions could result in serious personal injury, death, and/or property

damage.

• If means of connection to the supply connection box (wiring com-

partment) is other than grounded metal conduit, ground the pump

back to service using a copper conductor at least the size of the cir-

cuit conductors supplying the pump.

• Connect the ground wire to the grounding terminal in the wiring

compartment.

The number of ON/OFF power cycles for the pump must be less than 3

times per hour and less than 20/24 hours. If more frequent start/stop

cycles are required, the use of a dedicated start/stop input is recom-

mended. See 

External start/stop

 on page 10.

4.8.1  Power supply connection

WARNING:

Do not make any connection in the pump control box unless

the power supply has been switched off for at least 2 mi-

nutes.

For models with standard terminal block connection:
1. Open the terminal box cover removing the screws (5).

2. Thread the ½” NPT electrical fitting into the conduit connection of

the pump.

3. Connect the cable according to the wiring diagram.

a. Connect the ground wire, if used.

b. Connect the power wiring.

4. Close the terminal box cover.

4  Installation

ecocirc

®

 XL INSTRUCTION MANUAL

7

Содержание ecocirc XL

Страница 1: ...INSTRUCTION MANUAL P2002548 Rev E Single Phase Pump Three Phase Pump ecocirc XL...

Страница 2: ......

Страница 3: ...Connection assignment 9 5 System Description 9 5 1 User interface 9 5 1 1 User interface locking unlocking 9 5 2 Functions 9 5 2 1 Control Modes 9 5 2 2 Temperature dependent control modes 10 5 2 3 N...

Страница 4: ...lts causes and remedies 14 9 Other Relevant Documentation or Manuals 15 9 1 Embedded Software and Driver Software License Agreement 15 10 Product warranty 15 Table of Contents 2 ecocirc XL INSTRUCTION...

Страница 5: ...ar radiation unless Xylem has been informed and ap propriate actions have been agreed upon Recycling guidelines Always follow local laws and regulations regarding recycling 1 4 Spare parts WARNING Onl...

Страница 6: ...f the pump NOTICE Do not use this pump to handle liquids containing abrasive solid or fibrous substances toxic or corrosive liquids potable liquids other than water or liquids not compatible with the...

Страница 7: ...nual lifting or handling Always lift the pump by the motor housing or pump body If the pump weight exceeds the manual handling limits use lifting equipment with lifting straps A0022_a_sc 4 2 Tools req...

Страница 8: ...ra tion The current type and power supply voltage connection must corre spond to the specifications on the name plate on the pump Use wires at least 14 AWG to supply power to the pump Follow all local...

Страница 9: ...lb 1 2 M8 170 in lb 1 2 M10 340 in lb 3 M10 340 in lb CAUTION Check for the presence of leaks after reassembling the pump 4 8 Electrical installation Precautions WARNING Make sure that all connections...

Страница 10: ...e 7 Connection diagram for three phase models CAUTION Connect the low voltage circuits of the electronic drive only to Safety Extra Low Voltage SELV circuits The circuits pro vided for use with extern...

Страница 11: ...control indicator Hot Surface Burn hazard During normal operation the pump surfaces may be so hot that only the buttons should be touched to avoid burns 5 1 1 User interface locking unlocking The use...

Страница 12: ...d See Figure 6 Connection diagram for single phase models on page 8 Start stop terminals for three phase models are 13 and 14 See Figure 7 Connection diagram for three phase models on page 8 NOTICE Th...

Страница 13: ...l on www bellgos sett com NOTICE The differential sensor cables shall not exceed 65 ft 5 2 8 Communication bus The pumps have two built in RS 485 communication channels Single phase pumps The standard...

Страница 14: ...TE The communication setup menu is available only on display and not through communication bus 6 1 2 Change the control mode The pump can be controlled by a BMS Building management system or other dev...

Страница 15: ...y two pumps in parallel menu The following procedure must be executed during the start up phase of the pump 1 Enter the two pump sub menu when the display is showing TWMA two pump master or TWSL two p...

Страница 16: ...malfunction Switch off the pump for 5 minutes and then power on If the problem persists contact local B G repre sentative A02 High temperature of the fluid Check water temperature value A03 Automatic...

Страница 17: ...ch date of shipment shall not be greater than af ter receipt of notice that the goods are ready to ship whichever shall occur first unless a longer period is specified in the product documen tation th...

Страница 18: ...k e damaged due to abnormal con ditions vibration failure to properly prime or operation without flow f damaged due to a defective power supply or improper electrical protection or g damaged resulting...

Страница 19: ......

Страница 20: ...es and advanced analytics solutions for water electric and gas utilities In more than 150 countries we have strong long standing relationships with customers who know us for our powerful combination o...

Отзывы: