Xylem Ebro TLC 750 BT Скачать руководство пользователя страница 4

TLC 750 BT / TLC 750 NFC 
Operation Manual 

 

Page 4 

 

 

3. Safety instructions 

 

 

 

The device is not suitable for children. Keep out of the reach of children!

 

 
Risk of injury! 
There is a risk of injury when the probe needle is unfolded. 
Risk of contamination! In case of injuries with the probe needle you could 
contract dangerous germs! 
 
Burns! 
After measuring high temperatures, the probe needle still is hot for some 
time. 
 
Avoid over-tightening the penetration probe pivot. Overstressing the 
penetration probe may cause breakage. 
 
Operate the device only within the specified parameters. 
 

 

Warning of laser light! 
Risk of injury to the eyes! Do not aim the laser directly or indirectly via 
reflective surfaces to the eyes. 
 

 
 

 
4. Precautions 

 

Protect the thermometer from the following influences: 
 
• Strong electromagnetic fields e.g. induction heaters 
 
• Static electricity 
 
• Do not use on or near hot or very cold objects. 
 

 

 

Содержание Ebro TLC 750 BT

Страница 1: ...BA_TLC750_NFC_BT_ENG_07 Operation Manual Dual Radio Thermometer TLC 750 BT TLC 750 NFC ...

Страница 2: ... 4 Infrared temperature measurements 5 5 5 Logging modes 6 5 5 1 AdHoc logging mode 6 5 5 2 List logging mode 7 5 6 Settings Menu 8 5 6 1 Settings Menu Enter 8 5 6 2 Settings Menu Operation 8 5 6 3 Settings Menu Entries 9 6 What to do if 10 7 Battery indicator and charge 10 8 Care and Maintenance 10 9 Disposal 11 10 Technical specifications 12 11 Equipment 12 12 Standardize 13 13 Regulatory inform...

Страница 3: ... place 2 Overview The TLC 750 NFC and TLC 750 BT are both infrared and contact thermometers You can choose between these two types of measurement at any time While using them as an infrared thermometer two integrated laser pointers help to aim at the desired measuring surface The model variant TLC 750 BT has a Bluetooth LE interface integrated for wireless data transmission In addition the device ...

Страница 4: ... high temperatures the probe needle still is hot for some time Avoid over tightening the penetration probe pivot Overstressing the penetration probe may cause breakage Operate the device only within the specified parameters Warning of laser light Risk of injury to the eyes Do not aim the laser directly or indirectly via reflective surfaces to the eyes 4 Precautions Protect the thermometer from the...

Страница 5: ...diately when the penetration probe is closed 5 3 Penetration probe temperature measurements The Penetration probe must be unfolded for this mode of operation Position the probe needle where you want to measure the temperature Wait until temperature has stabilized By pressing button last measured temperature value is held until is pressed again 5 4 Infrared temperature measurements The penetration ...

Страница 6: ... button is shortly pressed In this state device alternately shows HOLD and SAVE If Bluetooth is connected measurement data is transferred via Bluetooth Only available at TLC 750 NFC device If button is pressed down the internal NFC reader searches every time once for NFC tags If a NFC tag was found device shows TAG and alternately HOLD and SAVE If Bluetooth is connected NFC tag data is transferred...

Страница 7: ...2 By use of or buttons it is possible to change measurement location 3 In infrared mode temperature measurements are taken while button is pressed In penetration probe mode temperature measurements are taken while no key is pressed 4 In infrared mode temperature value is held if button is released In penetration probe mode temperature measurement is held if button is shortly pressed In this state ...

Страница 8: ...ter that additionally button for 3 seconds 5 6 2 Settings Menu Operation If menu is entered it is possible to change current displayed menu entry by the and Buttons When button is pressed next menu entry is displayed If no button is pressed for 3 seconds next menu entry is displayed After last menu entry is displayed device starts measure mode ...

Страница 9: ...T Laser ON OFF Default ON EMIS IRT Emissivity 10 100 Default 95 AHLD Auto Hold function for penetration probe ON OFF Default ON LCDR LCD rotation setting ON OFF Default ON BLKL Backlight ON OFF Default ON BLE Bluetooth switch off timeout 30s ON OFF Default ON Only available at TLC 750 NFC device NFC NFC reader functionality ON OFF Default ON ...

Страница 10: ...essly using the base station IF 750 or the charger CS 750 Charging indicator Description Battery fully charged Charging completed Battery partially discharged Battery almost empty Charging active 8 Care and Maintenance Clean the lens Blow loose particles with clean compressed air Then carefully remove impurities with a soft brush Gently wipe the surface with a damp cotton ball Moisten the cotton b...

Страница 11: ...isposal If the device has become unusable it must be disposed of in a way that is appropriate for the environment Do not dispose of the device with household waste but do it according to the specific national requirements legislation regarding recycling ...

Страница 12: ...eight 130 g Dimensions L x B x T 169 5 x 44 x 23 mm Protection class IP65 Battery operating time typical 8h at continuous use Battery type 3 7V Lithium Polymer Battery charging USB Requirements for the external Power supply unit Limited Power Source according IEC60950 1 or PS2 classified IEC62368 1 Short circuit current 8A Wireless WPT by means of IF 750 or CS 750 Battery recharge time typical 3h ...

Страница 13: ...sion FCC warns the users that changes or modifications to the unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment FCC 15 105 b Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reason able protection ag...

Страница 14: ... including interference that may cause undesired operation of the device Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage 2 l utilisateur de l appareil doit accepter tout brouillage radioélectrique subi même si le brouillage est su...

Страница 15: ...nalytics Germany Sales GmbH Co KG ebro Dr Karl Slevogt Str 1 82362 Weilheim Germany Phone 49 0 841 954 78 0 Fax 49 0 841 954 78 80 Internet www ebro com E Mail ebro xyleminc com 15 Manufacturer information Xylem Analytics Germany GmbH Dr Karl Slevogt Str 1 82362 Weilheim Germany ...

Отзывы: