User Manual of Xyclop NVR
141
4.
Verify the switch is not flow control.
Check the brand, model of the switch connecting IP camera and NVR, and contact with the manufacturer
of the switch to check if it has the function of flow control. If so, please turn it down.
5.
Check whether the fault is solved by the step 1 to step 4.
If it is solved, finish the process.
If not, please contact the engineer from our manufacturer to do the further process.
No monitor connected with the NVR locally and when you manage the IP camera to connect with the
device by web browser remotely, of which the status displays as Connected. And then you connect the
device with the monitor via VGA or HDMI interface and reboot the device, there is black screen with
the mouse cursor.
Connect the NVR with the monitor before startup via VGA or HDMI interface, and manage the IP
camera to connect with the device locally or remotely, the status of IP camera displays as Connect. And
then connect the device with the CVBS, and there is black screen either.
Possible Reasons:
After connecting the IP camera to the NVR, the image is output via the main spot interface by default.
Steps:
1.
Enable the output channel.
2.
Select “Menu > Configuration > Live View > View”, and select video output interface in the drop-down
list and configure the window you want to view.
The view settings can only be configured by the local operation of NVR.
Different camera orders and window-division modes can be set for different output interfaces
separately, and digits like “D1”and “D2” stands for the channel number, and “X” means the selected
window has no image output.
3.
Check whether the fault is solved by the above steps.
If it is solved, finish the process.
If not, please contact the engineer from our manufacturer to do the further process.
Live view stuck when video output locally.
Possible Reasons:
a)
Poor network between NVR and IP camera, and there exists packet loss during the transmission.
b)
The motion detection and alarm functions are enabled, and the parameters of Main Stream (Normal) and
Main Stream (Event) are different. So the image looks stuck due to the image changes between different
resolutions.
c)
The frame rate has not reached the real-time frame rate.
Steps:
1.
Verify the network between NVR and IP camera is connected.
1)
When image is stuck, connect the RS-232 ports on PC and the rear panel of NVR with the RS-232
cable.
2)
Open the Super Terminal, and execute the command of “
ping
192.168.0.0
–l 1472 –f
”
(the IP address
may change according to the real condition), and check if there exists packet loss.
Simultaneously press
Ctrl
and
C
to exit the ping command.
2.
Check the parameters of Main Stream (Normal) and Main Stream (Event).
Select “Menu > Record > Parameters > Record”, and set the resolution of Main Stream (Event) the same as
the one of Main Stream (Normal).
3.
Verify the frame rate is real-time frame rate.
Содержание XC-4CH-NVR-1TB
Страница 1: ...Network Video Recorder XC 4CH NVR 1TB XC 8CH NVR 2TB User Manual...
Страница 9: ...User Manual of Xyclop NVR 9 Chapter 1 Introduction...
Страница 14: ...User Manual of Xyclop NVR 14 Chapter 2 Getting Started...
Страница 28: ...User Manual of Xyclop NVR 28 Chapter 3 Live View...
Страница 36: ...User Manual of Xyclop NVR 36 Chapter 4 Record Settings...
Страница 51: ...User Manual of Xyclop NVR 51 Chapter 5 Playback...
Страница 68: ...User Manual of Xyclop NVR 68 Chapter 6 Backup...
Страница 79: ...User Manual of Xyclop NVR 79 Chapter 7 Alarm Settings...
Страница 88: ...User Manual of Xyclop NVR 88 Chapter 8 Network Settings...
Страница 100: ...User Manual of Xyclop NVR 100 Chapter 9 HDD Management...
Страница 114: ...User Manual of Xyclop NVR 114 Chapter 10 Camera Settings...
Страница 118: ...User Manual of Xyclop NVR 118 Chapter 11 NVR Management and Maintenance...
Страница 128: ...User Manual of Xyclop NVR 128 Chapter 12 Others...
Страница 137: ...User Manual of Xyclop NVR 137 Appendix...