Operating Instructions
1. Fill the reservoir
③
with lukewarm water. Do not fill over the 24 oz/700
ml line.
2. Take the preferred nozzle
①
and install onto the handle
⑤
.
3. Connect the device to a power socket.
4. Press the on/off switch
⑦
to turn on the device.
5. Adjust the water pressure by turning the pressure control dial
⑧
and press
to switch to
pulse mode if desired. Pulse mode can also be adjusted to different
pressure level using the pressure control dial.
6. Place the nozzle
①
into the mouth and aim towards the teeth. Keep your
mouth
partially closed to avoid splashing.
7. Move the water switch
④
on the handle to ON and begin to floss.
8. Move the water switch
④
on the handle to OFF after flossing.
9. Empty any remaining water from the reservoir between uses. To fully
drain the
reservoir, aim the nozzle towards the sink and move the water switch
④
to ON and operate for 3 seconds.
10. Replace the handle into the bracket and press the on/off switch
⑦
to turn
off the device and unplug the power cord.
Note: The device will automatically shut off after 3 minutes of continuous
operation to avoid excessive gum cleaning which may cause damage.
Nozzle Inserting and Removing
Insert the nozzle into the hole at the top of the handle until you hear a click.
To remove, press then ozzle release button and pull the nozzle out.
Reservoir Filling
Lift the reservoir lid, remove the reservoir from the base and then fill with luke
warm water. Do not fill over the maximum level. Replace the reservoir on to
the base an d put back the lid after filling.
Mode Setting
Turn the pressure dial to adjust preferred water pressure from 20-130 psi with
an accuracy of 5 psi. Press the dial to switch between general cleaning mode
and pulse mode. The pressure adjustment can be applied for general
cleaning mode and pulse mode.
Oral Application Guidelines
It is possible that some minor gum bleeding occurs with healthy gums during
the first 1-2 weeks of application due to sensitive periodontal areas. Periodontal
or other diseases may be indicated if bleeding continues after 2 weeks of use.
In this case , stop using the device and consult a dentist. If your physician
advised you to receive antibiotic premedication before dental procedures, you
should consult your dentist before using this instrument or an y other oral hy
giene aid.
1. Lean over the sink, aim the nozzle towards your teeth and move the water
switch to ON to be gin floss.
2. Start with t he molar area (the back teeth) and move along the gum line
toward the front teeth, pausing briefly between each tooth. Continue until all
areas around and between the teeth have been cleaned.
3. When cleaning, hold the nozzle at a 90-degree angle to your gum line. Keep
your mouth partially closed to avoid splashing, but all ow water to spill from
your mouth in to the sink.
90°
4. Do not direct the stream toward periodontal pockets except using the
periodontal nozzle.
29