ASSEMBLY
4
The Fuel System:
The hose/regulator assembly attaches to the propane gas supply.This provides fuel to
the heater.
The Ignition System:
The piezo ignitor lights the burner fuel supply on the machine.
The Automatic Control System:
The automatic control valve shuts off the heater if the flame goes out.
Propane supply
You must provide propane gas and tank(s). Use this heater only with a propane vapor withdrawal supply
system. Installation must conform to local codes or, in the absence of local codes,with the standard for the
Storage and Handling of Liquefied Petroleum Gases ANSI/NFPA 58 and the Natural Gas and Propane
Installation Code CSA B149.1.Your local library or fire department will have this booklet. The amount of
propane gas ready for use from propane tanks varies.Two factors decide this amount:
1.
The amount of
liquid propane gas in tank(s).
2.
The temperature of tank(s). The chart below shows the minimum number
of 100 pound tanks or one larger tank may be needed in colder weather.Your local propane gas dealer will
help you select proper supply system.
WARNING:
Provide at least a 2.5
square feet (23 square meters)
opening of fresh, outside air while
running heater. If proper fresh,outside
air ventilation is not provided, carbon
monoxide poisoning can occur.
Provide proper fresh, outside air
ventilation before running heater.
1.
Connect the regulator to the gas valve, clockwise.
ASSEMBLY
2.
Connect the regulator to the gas tank, clockwise.
Содержание 96956