Maintain and clean chlorine generator electrolytic cell
Before taking out the electrolytic cell, disconnect the power supply of chlorine generator.
After removal, check whether there is scaling (light-colored hard skin or flaky sediment)
between titanium plates and some debris stuck on the electrode plate of the electrolytic
cell. If there is sediment, try to rinse it off with a high-pressure water pipe. If this is not
successful, the electrolytic cell may need to be replaced. Titanium scale indicates that the
pool is at a high calcium level. If this cannot be corrected, it needs to clean the electrolytic
cell regularly.
6. Replace the flow switch
After long-term usage, the water flow switch may be damaged. We provide accessories
that can be directly replaced. Please refer to the following figures for replacement.
Unscrew the external flow switch, reinstall and connect it to the controller
.
Pay
attention to the direction of flow switch installation when replacing
8