E. Adjusting the timer function:
1.
While the blower (motor) is not running, touch and hold Decrease Value button over 3 seconds to
enter timer mode.
2.
Adjust to desired period of delay off timer by touching Increase Value or Decrease Value
button
(minimum 1 minute to maximum 15 minutes). This setting will be saved immediately.
F. Activating the timer function:
* While the blower (motor) is running, touch and hold Power button for over 3 seconds to activate delay
off timer. Power-off delay indicator will light up and power-off delay digital timer will begin to
countdown, when it reaches zero, the blower (motor) will shut down.
G. To clear cleaning reminder:
•
When blower (motor) starts to rotate, cumulative running time will be shown in
Power-On Elapsed
Digital Timer
. This timer icon flashes when 30 hours is up and reminds user to clean the baffle filters.
•
After cleaning the filters and when the motor is not in use, touch and hold (+)
Increase Value
button
over 3 seconds to reset the timer. Please note that turning off the system will not reset the
Power-On
Elapsed Digital Timer
.
F. AUTOMATIC SHUT OFF:
•
MACHINE WILL AUTOMATICLY SHUT OFF AFTER APPROX. 2 ½ HOURS (FOR THOSE
MANUFACTURED AFTER AUGUST 2012 ONLY)
3. TYPE 3: SOFT PRESS BUTTON CONTROL (For All Ultra Series)
SPECIFICATION:
Body Design
Seamless Stainless Steel, Satin Finish
Power Rating
120V/60Hz (USA & Canada standard)
General Input Power
184W (90W + 2x2W)
Motor Input Power
90 W each
Ampere
1.70 A
Levels Of Speed Control
4 Levels
Airflow
(Q/L/M/H) 280CFM / 460CFM / 670CFM / 900CFM
Noise Level
(Q/L/M/H) 1.2Sone(43dB) / 2.8Sone(55dB) / 5.0Sone(63dB) / 6.5 Sone(67dB)
Number Of Motors
2 Motors
Motor Type
Single Chamber Ultra Quiet
Fan Type
Centrifugal Squirrel Cage
Filtration Type
Heavy Duty Stainless Steel Baffle Filter
Illumination
LED light, 2W Maximum
Venting Size
Top, 8 inches Round
Interference Protection
Radio Frequency Interference Protected
Note
Specification subject to change without notice, contact your local reseller for details.
A. Activating Normal Blower Function
•
Press (2) for lowest speed
•
Press (3) for medium speed
•
Press (4) for highest speed
B. To turn off the power:
•
Press (1)
C. To turn the light ON/OFF:
•
Press (5) once to turn on, press again to turn off
11