8
Model
UL14-U30 / UL14-U36 / PX14-U30 / PX14-U36
Body Design/Material
Seamless Stainless Steel, Satin Finish. 1.0 mm Non-Magnetic 201 S.S
Power Rating
120V/60Hz (USA & Canada standard)
General Input Power
184W
Motor Input Power
90W x 2
Ampere
1.7A
Control Type
Mechanical Button
Levels Of Speed Control
UL series: 3 Levels, PX series: 4 levels
Noise Level
1.5-6.5 sones or 33-55 dB
Number Of Motors
2 Motors
Motor Type
Single Chamber Ultra Quiet
Fan Type
Centrifugal Squirrel Cage Blower
Filtration Type
Heavy Duty Stainless Steel Baffle Filter
Illumination
LED light, 2W Maximum
Venting Size
Top, 8 inches Round
Note
Specification subject to change without notice, contact your local reseller for details.
1. If the range hood or lights does not operate after installation:
Check if the range hood has been plugged in. Make sure that all power has been turned back ON.
Swap out light assembly to working ones to deter mine whether it is caused by defective bulbs.
2. The range hood vibrates when the blower is on:
The range hood might not have been secured properly to the cabinet or wall.
Check if the blower wheel is damaged.
3. The blower or fan seems weak:
Check that the duct sized used is at least 6”. Range hood WILL NOT function efficiently with insufficient duct size & loosely secured.
Check if duct is clogged or if damper unit (half-circular flapper) is not installed correctly or opening properly. A tight mesh on a side wall cap unit might
also cause restriction to the air flow.
4. The lights work but the blower is not spinning at all, is stuck or is rattling.
The blower might be
jammed or scraping the bottom due to shipping damage. Please contact us immediately.
5.
The hood is not venting out properly
:
Make sure the distance between the stove top and the bottom of the hood is within 26” and 30” in distance.
Reduce the number of elbows and length of ductwork. Check if all joints are properly connected, sealed, and taped.
Make sure the power is on high speed for heavy cooking.
6. The hood is noisier than normal
The damper was not opened.
The duct is not secure and causes vibration.
The smaller duct size than required is being used.
7. Control panel is not active
Check to make sure the auto function is not on.
11. SPECIFICATION
12. TROUBLESHOOTING
A.Make sure the range hood is unplugged or turn OFF breaker.
B.Pop out the light by pressing behind the light fixture.
C.Install new light bulb.
D.Put the light set back by pressing it in.
E.Plug in and range hood to test for operation.