www.XtremeAirUsa.com
PAGE
7
A. ACTIVATING BLOWER FUNCTION:
Option 1: Touch and hold down (+) for 1-2 seconds.
Option 2: Touch and hold down power sign (1) for 1-2 seconds. (The blower will be running at the same speed as last used).
Note
: The system saves user configurations, settings such as timer and blower (motor) speed will remain the same the next time it is turned on.
B. ADJUSTING BLOWER SPEED:
Touch and hold down (+) for increase.
Touch and hold down (-) for decrease.
C. TURNING OFF THE BLOWER:
Touch and hold down power sign (1) for 1-2 seconds.
D. TO TURN THE LIGHT ON/OFF:
Touch Light button (6) once to turn on the lights, and once again to turn off the lights.
E. ADJUSTING THE TIMER FUNCTION:
While the blower (motor) is not running, touch and hold Decrease Value button (2) over 3 seconds (until it’s flashing) to enter timer mode.
Adjust to desired period of delay off timer by touching Increase Value or Decrease Value
button (minimum 1 minute to maximum 15 minutes).
This setting will be saved immediately.
F. ACTIVATING THE TIMER FUNCTION:
While the blower (motor) is running, touch and hold “Power” button (1) for over 3 seconds to activate delay off timer.
Power-Off Delay Timer Indicator
(10) will light up and
Power-Off Delay Digital Timer
(9) will begin to countdown. When it reaches zero, the blower (motor) will shut down.
G. TO CLEAR CLEANING REMINDER:
When blower (motor) starts to rotate, cumulative running time will be shown in
Power-On Elapsed Digital Timer (8)
. This timer icon flashes when 30 hours
is up and reminds user to clean the baffle filters.
After cleaning the filters and when the motor is not in use, touch and hold (+)
Increase Value
button (7) over 3 seconds to reset the timer. Please note
that turning off the system will not reset the
Power-On Elapsed Digital Timer (8)
.
Body Design
Non-Magnetic 1.0 mm Stainless Steel, Satin Finish
Power Rating
120V/60Hz (USA & Canada standard)
General Input Power
158W (150W + 4x2W)
Motor Input Power
150 W each
Ampere
1.3 A
Levels Of Speed Control
4 Levels
Maximum Airflow
900CFM
Noise Level
Approximately 1.5 – 6.0 sones or 33 – 54 dB
Number Of Motors
Single Motor
Motor Type
Single Chamber Ultra Quiet
Fan Type
Squirrel Cage blower
Filtration Type
Heavy Duty Stainless Steel Baffle Filter
Illumination
4 LED lights, 2W Maximum/each
Venting Size
Top 6 inches Round
Interference Protection
Radio Frequency Interference Protected
Note
Specification subject to change without notice.
1. If the range hood or lights does not operate after installation:
Check if the range hood has been plugged in. Make sure that all power has been turned back ON. Check if the fuse is not blown and all electrical wiring is
properly connected.
Swap out light assembly to working ones to deter mine whether it is caused by defective bulbs. See
replacing the light bulbs
on Page 13.
2. The range hood vibrates when the blower is on:
The range hood might not have been secured properly on to the ceiling or wall.
Check if the motor is secured in place. If not, then tighten the motor in place. Check if the blower wheel is damaged.
11. SPECIFICATION