![Xtreme XC-14A Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/xtreme/xc-14a/xc-14a_user-and-installation-manual_890807008.webp)
Power
Cord
Holder
1.
Remove
the
Power
Cord
Holder
from
the
accessory
box
2.
Place
the
Power
Cord
Holder
on
the
rear
of
the
unit
as
shown
in
Figure
3
3.
Use
screws
to
install
the
Power
Cord
Holder
to
the
rear
of
the
unit
(screws
inside
the
accessory
box)
Figure
3
–
Power
Cord
Holder
attachment
Rubber
Stoppers
1.
Remove
the
Rubber
Stoppers
from
the
accessory
box
2.
Place
the
Rubber
Stoppers
on
the
rear
of
the
unit
as
shown
in
Figure
4
3.
Use
screws
to
install
the
Rubber
Stoppers
to
the
rear
of
the
unit
(screws
inside
the
accessory
box)
Figure
4
–
Rubber
Stopper
attachment
Page
8
Xtreme
Power
Conversion®
(XPC)
Corporation
XC
‐
14A,
XC
‐
22A,
XC
‐
30A
USER’S
MANUAL
Portable
Air
Conditioners
Xtreme
Power
Conversion®
(XPC)
Corporation
Page
17
XC
‐
14A,
XC
‐
22A,
XC
‐
30A
USER’S
MANUAL
Portable
Air
Conditioners
Troubleshooting
Chart
Symptom
Possible
Causes
Corrective
Action
Water
leakage
High
water
level
in
condensate
tank
Remove
blockage
from
drain
hose
Remove
any
object
stuck
underneath
of
the
black
panel
under
the
water
tank
The
unit
doesn’t
work
Check
the
utility
to
verify
that
power
is
available
to
the
unit
Verify
that
the
power
cord
is
connected
Reset
the
circuit
breaker
and
restart
the
unit
Connect
the
power
cord
No
cold
air
flows
from
the
cold
air
outlet
Ambient
air
cannot
be
properly
cooled
if
the
filter
is
dirty
and
not
regularly
cleaned
Only
the
fan
operates
for
2
minutes
after
the
unit
has
been
started
to
protect
the
unit
The
ambient
air
temperature
may
be
too
high
Clean
air
filter
Verify
that
2
minutes
have
passed
since
the
unit
was
turned
on
The
temperature
of
the
compressor
can
be
higher
when
the
ambient
temperature
is
too
high.
The
compressor
will
not
work
unless
the
ambient
air
temperature
is
within
the
acceptable
operating
range
of
the
unit
Water
flow
can
be
heard
after
compressor
shuts
off
No
cause
Common
to
hear
coolant
flowing
after
unit
shuts
off
Alarm
displays
“FT”
with
less
than
half
of
the
condensate
water
in
the
tank
Spring
is
possibly
broken
Replace
the
spring
(see
Maintenance
section)