5.

 

SET

 

TEMP

 

BUTTON

 



Change

 

target

 

temperature

 

/

 

data

 

value

 

by

 

±

 

1.

 



Change

 

data

 

value

 

by

 

±

 

10

 

by

 

pressing

 

continually.

 



Press

 

the

 

SET

 

TEMP

 

BUTTONS

 

to

 

set

 

temperature

 



Upper

 

button

 

is

 

to

 

heighten

 

temperature

 

and

 

Lower

 

button

 

is

 

to

 

lower

 

temperature.

 

6.

 

ALARM

 



Alarm

 

indicator

 

light

 

blinks

 

and

 

indicates

 

abnormal

 

system

 

operation.

 



If

 

Alarm

 

occurs,

 

compressor

 

stops.

 



System

 

operation

 

stops

 

when

 

ALARM

 

light

 

is

 

activated

 

/

 

blinking

 

longer

 

than

 

3

 

minutes.

 

7.

 

CURRENT

 

TEMP

 



Displays

 

current

 

room

 

temperature

 

in

 

display

 

in

 

Fahrenheit

 

(in

 

ROOM

 

COOL

 

MODE

 

only)

 



SPOT

 

/

 

COOL

 

Mode

 

displays

 

outlet

 

(cool

 

air)

 

temperature

 

during

 

normal

 

operations.

 



In

 

order

 

to

 

change

 

°F

 

to

 

°C,

 

press

 

SPOT

 

/

 

COOL

 

and

 

ROOM

 

/

 

COOL

 

buttons

 

together

 

for

 

2

 

seconds.

 



C

 

will

 

blink

 

2

 

times

 

and

 

the

 

figure

 

will

 

change

 

to

 

°C

 



ALARM

 

codes

 

blink

 

and

 

are

 

displayed

 

when

 

abnormal

 

operation

 

occurs.

 

8.

 

TARGET

 

TEMP

 



Displays

 

the

 

unit

 

set

 

temperature

 

for

 

ROOM

 

COOL

 

mode

 

only

 

MAINTENANCE

 

Filter

 

Cleaning

 

There

 

are

 

two

 

filters

 

in

 

the

 

unit.

 

The

 

evaporator

 

filter

 

is

 

located

 

at

 

the

 

front

 

of

 

the

 

unit.

 

The

 

condenser

 

filter

 

is

 

located

 

in

 

the

 

rear

 

of

 

the

 

unit

 

(see

 

Figure

 

9

 

&

 

10).

 

 

 

 

Pull

 

the

 

filter

 

frame

 

forward

 

to

 

remove

 

the

 

back

 

filter.

 

 
 
 
 
 
 

Figure

 

7

 

 

Removing

 

Rear

 

Filter

 



Remove

 

dust

 

from

 

the

 

filter

 

using

 

a

 

vacuum

 

cleaner

 

hose

 

attachment.

 



If

 

required,

 

was

 

the

 

filter

 

in

 

lukewarm

 

water

 

with

 

a

 

mild

 

detergent.

 

Leave

 

to

 

dry

 

in

 

a

 

shaded

 

area

 

before

 

reinstalling.

 

Figure

 

8

 

 

Cleaning

 

the

 

Filter

 

1.

 

To

 

clean

 

the

 

evaporator

 

filter,

 

pull

 

the

 

front

 

filter

 

guard

 

forward

 

from

 

the

 

top

 

until

 

the

 

guard

 

is

 

open

 

(in

 

an

 

angled

 

position)

 

and

 

resting

 

on

 

the

 

supporting

 

cables.

 

2.

 

Slide

 

the

 

filter

 

up

 

and

 

use

 

a

 

vacuum

 

cleaner

 

to

 

remove

 

the

 

dust

 

from

 

the

 

filter.

 

3.

 

If

 

the

 

filter

 

is

 

heavily

 

covered

 

with

 

dust

 

and

 

dirt,

 

warm

 

water

 

and

 

mild

 

soap

 

or

 

neutral

 

detergent

 

may

 

be

 

used

 

to

 

wash

 

the

 

filter.

 

Do

 

not

 

use

 

any

 

other

 

chemicals

 

to

 

clean

 

the

 

filter,

 

as

 

they

 

will

 

likely

 

damage

 

the

 

filter.

 

4.

 

Dry

 

the

 

filter

 

in

 

a

 

shaded

 

area

 

before

 

replacing

 

it.

 

Do

 

not

 

operate

 

the

 

unit

 

without

 

the

 

filter

 

installed

 

and

 

the

 

filter

 

guard

 

in

 

the

 

Содержание XC-14A

Страница 1: ...le Air Conditioners Models XC 14A XC 22A XC 30A User s Installation Manual Xtreme Power Conversion XPC Corporation XC 14A XC 22A XC 30A USER S MANUAL Portable Air Conditioners Page 24 Xtreme Power Conversion XPC Corporation ...

Страница 2: ...ting Chart SPECIFICATIONS 18 SHIPPING LIST 19 OBTAINING SERVICE 20 XTREME POWER CONVERSION XPC CORPORATION LIMITED WARRANTY 21 OPTIONS 23 Ambient Air Adaptor Cooling Hose Assembly Temperature Sensor Line Remote Control Pump Kit XC 14A XC 22A XC 30A USER S MANUAL Portable Air Conditioners Page 2 Xtreme Power Conversion XPC Corporation OPTIONS Ambient Air Adaptor Cooling Hose Assembly Exhaust Flange...

Страница 3: ...the equipment has been used or stored in a manner contrary to the equipment s operating manual intended use or other written instructions Any technical advice furnished by XPC Corporation or a XPC Corporation authorized representative before or after delivery with regard to the use or application of Xtreme Power Conversion equipment is furnished on the basis that it represents XPC Corporations bes...

Страница 4: ...he outside of all packages Xtreme Power cannot accept any package without the RMA number marked on the outside of the boxes 4 Return the Xtreme Cooling unit by insured prepaid carrier to the address provided by the Technician Refer to the Warranty statements in this manual for additional details on what is covered XTREME POWER CONVERSION XPC CORPORATION LIMITED WARRANTY Xtreme Power Conversion XPC...

Страница 5: ...ervice center Xtreme Power Conversion XPC Corporation Page 5 XC 14A XC 22A XC 30A USER S MANUAL Portable Air Conditioners OBTAINING SERVICE If the Xtreme Cooling unit requires Service 1 Use the TROUBLESHOOTING section in this manual to eliminate obvious causes 2 Verify there are no circuit breakers tripped 3 Call your dealer for assistance If you cannot reach your dealer or if they cannot resolve ...

Страница 6: ...ea is not practical or possible A dedicated spot cooling thermostat controls the unit in this application These air conditioners can also be used in smaller areas for room cooling A control panel provides ease of use and contains self diagnostic functions and displays showing operating modes room and set temperatures and faults If an abnormal operation occurs a visual display of the fault is shown...

Страница 7: ... 0 x 24 4 x 50 4 22 0 x 24 4 x 50 4 Weight LBS 132 198 209 Current Consumption AMPS 11 5 11 0 10 0 15 0 14 0 Circuit Breaker Size AMPS 15 15 20 Power Consumption KW 1 4 2 3 3 1 Compressor Input KW 1 2 2 0 2 4 Air Flow High Low Evaporator CFM 357 285 464 393 571 500 Air Flow Condenser CFM 610 857 1142 Motor Input High Low Evaporator KW 0 091 0 089 0 24 0 20 0 13 0 11 Motor Input Condenser KW 0 08 0...

Страница 8: ...e blockage from drain hose Remove any object stuck underneath of the black panel under the water tank The unit doesn t work Check the utility to verify that power is available to the unit Verify that the power cord is connected Reset the circuit breaker and restart the unit Connect the power cord No cold air flows from the cold air outlet Ambient air cannot be properly cooled if the filter is dirt...

Страница 9: ...act a qualified service agent Replace compressor Condensate water level alarm Condensate tank is full Empty the water tank After installation of the water tank press the SPOT COOL or ROOM COOL button to resume operation Page 16 Xtreme Power Conversion XPC Corporation XC 14A XC 22A XC 30A USER S MANUAL Portable Air Conditioners Xtreme Power Conversion XPC Corporation Page 9 XC 14A XC 22A XC 30A USE...

Страница 10: ...andles to a flat level surface and set the cater brakes to the locked position Plugging in the Unit Check the prongs and surface of the power cord plug for dust dirt If dust and or dirt are present wipe off with a clean dry cloth Check the power cord plug and prongs for damage or excess play If any damage or excess play is found contact a qualified repair technician or a qualified electrician to p...

Страница 11: ...6 To clean the condenser filter lift up on the rear filter from the middle bar slightly and then angle the filter outwards from the bottom and remove 7 Use the same cleaning procedure as in steps 3 5 above 8 To replace the condenser filter place the top of the filter in the guide and slide the filter up until the bottom of the filter clears the frame Then push the bottom of the filter into the gui...

Страница 12: ...d when abnormal operation occurs 8 TARGET TEMP Displays the unit set temperature for ROOM COOL mode only MAINTENANCE Filter Cleaning There are two filters in the unit The evaporator filter is located at the front of the unit The condenser filter is located in the rear of the unit see Figure 9 10 Pull the filter frame forward to remove the back filter Figure 7 Removing Rear Filter Remove dust from ...

Отзывы: