Xtreme C60-800 Скачать руководство пользователя страница 9

Xtreme Power Conversion Corporation

C60 User’s Manual

Page 9

Uninterruptible Power Supply

Xtreme Power Conversion Limited Warranty

Xtreme Power Conversion (XPC) Corporation warrants Xtreme Power Conversion equipment, when properly ap‐

plied and operated within specified conditions, against faulty materials or workmanship for a period of 

two years 

for C60 Series products 

from the date of purchase. XPC Corporation warrants 

internal batteries for a period of 

two years

 from the date of purchase. For equipment sites within the United States and Canada, this warranty cov‐

ers repair or replacement, at the sole discretion of XPC Corporation. The customer is responsible for the costs of 

shipping the defective product to XPC Corporation. XPC Corporation will pay for ground shipment of the repaired 

or replacement product. This warranty applies only to the original purchaser.

If equipment provided by XPC Corporation is found to be 

Dead‐on‐Arrival (DOA)

, XPC Corporation will be respon‐

sible for the costs of shipping product to and returning equipment from the customer in a timely manner as agreed 

to with the customer, once the customer has requested and received a 

Return Material Authorization (RMA)

 

number. DOA equipment is defined as equipment that does not properly function according to user documenta‐

tion when initially received and connected in conjunction with proper procedures as shown in the user documen‐

tation or via support provided by XPC Corporation personnel or authorized agents.

This warranty shall be void if (a) the equipment is repaired or modified by anyone other than XPC Corporation or 

a XPC Corporation approved third party; (b) the equipment is damaged by the customer, is improperly used or 

stored, is subjected to an adverse operating environment, or is operated outside the limits of its electrical specifi‐

cations; or (c) the equipment has been used or stored in a manner contrary to the equipment’s operating manual, 

intended use or other written instructions. Any technical advice furnished by XPC Corporation or a XPC Corpora‐

tion authorized representative before or after delivery with regard to the use or application of Xtreme Power Con‐

version equipment is furnished on the basis that it represents XPC Corporations best judgment under the situation 

and circumstances, but it is used at the recipient’s sole risk.

EXCEPT AS STATED ABOVE, XPC Corporation DISCLAIMS ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING 

WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

EXCEPT AS STATED ABOVE, IN NO EVENT WILL XPC Corporation BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCI‐

DENTAL, OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF Xtreme Power Conversion EQUIPMENT, 

including but not limited to, any costs, lost profits or revenue, loss of equipment, loss of use of equipment, loss 

of software, loss of data, cost of substitutes, or claims by third parties. Purchaser’s sole and exclusive remedy for 

breach of any warranty, expressed or implied, concerning Xtreme Power Conversion equipment, and the only 

obligation of XPC Corporation under this warranty, shall be the repair or replacement of defective equipment, 

components, or parts; or, at XPC Corporations sole discretion, refund of the purchase price or substitution of an 

equivalent replacement product. 

[email protected]

24/7 Technology Inc

1349 Old 41 Hwy Suite 135, Marietta, GA 30060  

Phone:  (770) 971 8480 Fax: (770) 514 8415

www.247technology.com

Содержание C60-800

Страница 1: ...60 Standby UPS 800VA Models User Installation Manual 2015 Xtreme Power Conversion Corporation All rights reserved Rev 6 23 15 For more information visit www 247technology com on line ups c60 standby ups ...

Страница 2: ...ninterruptible Power Supply Table of Contents Package Contents 3 ProductIntroduction 3 Product Overview 3 Installation Initial Startup 4 Indicators Alarm Conditions 5 Troubleshooting 6 Specifications 7 Obtaining Service 8 Xtreme Power Conversion Limited Warranty 9 ...

Страница 3: ... set up your system for the maximum safety and performance Included is information on customer support and service if it is required If you experience a problem with the UPS please refer to the Troubleshooting section in this manual to correct the problem If the problem is not corrected please collect in formation so that the Technical Support personnel can more effectively assist you Product Over...

Страница 4: ... on the front of the UPS For best results the batteries in the UPS should be charged for at least 8 hours before use The UPS charges its battery while it is connected to AC utility power and powered on Connecting the Loads Plug the loads to be supported by the UPS into the output receptacles on the rear of the UPS Simply turn the power switch on the UPS on and the devices connected to the UPS will...

Страница 5: ...ric shock and high short circuit current The following precaution should be observed when working on batteries Remove watches rings or other metal objects Use tools with insulated handles To reduce the risk of electric shock disconnect the UPS from the main supply before installing a computer inter face signal cable Reconnect the power cord only after signaling interconnections have been made Serv...

Страница 6: ...d Remove some of the load from the output of the UPS UPS fault Return the unit for service Alarm sounds every 2 seconds when the AC input is normal Battery defect Replace the battery with the same type of battery Charging circuit is damaged Return the unit for service When power fails backup time is shorter than expected The UPS is overloaded Remove some of the load from the output of the UPS Batt...

Страница 7: ...ated sine wave battery mode Transfer time 2 6 ms Outlets 2 NEMA 5 15R 2 IEC C13 Overload capacity 110 20 10 for 5 min 120 20 10 immediately off Efficiency 95 BATTERY UPS battery type 1 12V 9AH 12VDC UPS charge current 1A maximum Recharge time 8 hours to 90 capacity PHYSICAL Dimensions W x D x H 4 0 x 13 0 x 5 7 in Weight 7 5 lbs ENVIRONMENT Temperature 32 104 F 0 40 C Humidity 0 90 Altitude 11 500...

Страница 8: ...sk you for the above information and if possible help solve your problem over the phone In the event that the unit requires factory service the technician will issue you a Return Mate rial Authorization number RMA If you are returning the UPS to Xtreme Power for service please follow these procedures 1 Pack the UPS in its original packaging If the original packaging is no longer available ask the ...

Страница 9: ...PC Corporation approved third party b the equipment is damaged by the customer is improperly used or stored is subjected to an adverse operating environment or is operated outside the limits of its electrical specifi cations or c the equipment has been used or stored in a manner contrary to the equipment s operating manual intended use or other written instructions Any technical advice furnished b...