background image

PARTS LIST

12

Содержание 90154

Страница 1: ...ON MAINTENANCE AND CLEANING PROCEDURES WRITE THE PRODUCT S SERIAL NUMBER ON THE BACK OF THE MANUAL NEAR THE ASSEMBLY DIAGRAM OR MONTH AND YEAR OF PURCHASE IF PRODUCT HAS NO NUMBER OWNER S MANUAL AND SAFETY INSTRUCTIONS ITEM 90154 90155 90156 FOR QUESTIONS PLEASE CALL OUR CUSTOMER SUPPORT 909 628 0880 MON FRI 9AM TO 3PM PST ...

Страница 2: ...erial CFPT can not make sure any other equipments in or around pool will not corrosion Avoid chlorine gas build up When pump is OFF A build up of flammable gases will result in hazardous conditions Add acid to water do not do opposite CHEMISTRY TIPS New Pool Water Arecently filled or newly refinished pool may contain undesirable matter This undesirable matter could interfere with the CFPT ability ...

Страница 3: ...can test for nitrates and phosphates While a 0 ppm level of nitrates is the ideal the pool owner should make sure that nitrates DO NOT exceed 10 ppm IDEAL WATER CHEMISTRY LEVEL How to test chlorine It is recommended that chlorine test samples be taken from two 2 locations in the pool Compare the samples A higher level should be found at the pool return line The higher level at the pool return line...

Страница 4: ...on must be made to total alkalinity We subtract 1 3 of the cyanuric acid level from the reading obtained in the total alkalinity test Total Alkalinity 1 3 Cyanuric Acid Corrected Alkalinity This correction can be considerable in established pools with high cyanuric acid levels for example at 100 ppm cyanuric acid the correction amounts to 33 ppm 100 3 33 3 NOTE Use the reading on the chart that is...

Страница 5: ...4 APPLICATIONS POUNDS and Kg OF SALT NEEDED FOR 3400 PPM ...

Страница 6: ...n addition the Electrolytic Cell continuously shocks the incoming water burning off any oils organic matter or other particles that need to be oxidized Best of all the process continuously recycles the salt after cleaning the pool the original molecules reform and the whole process begins again The salt doesn t get used up CFPT Salt Chlorinator consist of Cell unit and Power Center Cell unit has L...

Страница 7: ...uildup can occur The CFPT should never be energized when the pool pump is OFF and water is not flowing through the unit Ensure to Install Chlorine Bromine Feeders after CFPTCell When using the CFPT with an in floor cleaning system it is recommended that a separate return line be used for the cleaner to reduce the increased water pressure stress on the CFPT cell Loop Plumbing Diagram CFPT is design...

Страница 8: ...eady COLD WATER It warns water temperature either below 10 C or above 50 C system off SALT GOOD LED ON Good salt It shows the Ideal Salinity 2800 PPM to 4500 PPM INSPECT SALT RED ON Salt Level below 2300 PPM or above 6000 PPM INSPECT SALT RED flashing Salt Level 2300 PPM to 2800 PPM 4500 PPM to 6000 PPM CELL GOOD LED ON The cell is good and producing chlorine INSPECT CELL RED The cell needs to be ...

Страница 9: ... the time of pool start up until the chlorine level has returned to 2 0 to 4 0 ppm before switching on the CFPT Output Settings and Adjustments Chlorine output is show by LED DISPLAY before working there will be 1 2 minutes self checking the salt level If salt is in the normal level it will begin working if not adjust according to the warning showed on the LED DISPLAY For example if salt level at ...

Страница 10: ...Using PVC glue mount the PVC couplings to the plumbing pipe Allow the glue to dry 2 Mount the cell vertically Allow access to the cell operator control panel Install the cell onto the couplings Ensure the O rings are seated properly 3 Switch on the pump and visually inspect for leaks around the couplings Connecting CFPT Cell Cable to the Power Center WARNING Switch OFF main system power to the Pow...

Страница 11: ...ressure at the relief valve it is usually on top of your pool filter Step 3 Unscrew the threads on both sides of the original T cell Step 4 Original AquaRite Turbo Cell out from the piping Step 5 Pull the plug out at the lower corner of the digital controller Step 6 Inspect the O rings inside the union connected with the pipe for any wear and replace them if possible Apply a thin layer of lubrican...

Страница 12: ...the power cord into the lower corner of the controller Step 9 Restart the pool pump and salt chlorine generator The controller should light up and the pool pump should operate Step 10 Any air in the duct should be drained from the open safety valve When the water begins to squirt from the safety valve close the valve Step 11 After a couple of minutes the controller display will show a salt value o...

Страница 13: ...PARTS LIST 12 ...

Страница 14: ...TROUBLESHOOTING 13 ...

Страница 15: ...e sent to the pool automation control display 7 Software revision level 8 Cell type On the 8th push of the button the display will revert back to the default salt display Also if the button is not pushed for 30 seconds the display will revert back default salt Diagnostic Displays Power LED not on Check to make sure 120 240 VAC input power is connected to the control Be sure the jumpers are set pro...

Страница 16: ... STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIEDAND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO Record Product s Serial Number Here Note If product has no serial number r...

Отзывы: