background image

IMPORTANT SAFETY INFORMATION

This filter operates under high pressure. When any part of the circulating system (e.g., clamp, pump, filter, 
valves, etc.) is serviced, air can enter the system and become pressurized. Pressurized air can cause the 
lid or control valve to separate which may result in serious injury, death, or property damage. To avoid this 
potential hazard, follow these instructions.
1. Before repositioning valves and before beginning the assembly,
disassembly, or adjustment of the clamp or any other service of the circulating system:
(a) Turn the pump off and shut off any automatic controls to ensure the system is not inadvertently started 
during the servicing;
(b) Open manual air relief valve;
(c) Wait until all pressure is relieved, pressure gauge must read zero (0).
2. Whenever installing the filter clamp, follow the filter valve and clamp installation instructions exactly.
3. Once service on the circulating system is complete, follow system restart instructions exactly.
4. Maintain circulation system properly. Replace worn or damaged parts immediately.

Failure  to  operate  your  filter  system  or    inadequate  filtration  can  cause  poor  water  clarity  obstructing 

visibility in your pool and can allow diving into or on top of obscured objects, which can cause serious 

personal injury or drowning.

This filter operates under pressure. With the valve clamped properly and operated without air in the

system, this filter will operate in a safe manner. Air entering the filter and the valve not clamped

correctly can cause the valve to separate, which could cause serious personal injury and/or property

damage.
Always turn pump off before changing valve positions. Changing valve positions while the pump is running 

can damage the control valve, which may cause serious injury or property damage.
Chemical fumes and/or spills can cause serious corrosion to the filter and pump structural components. 

Structurally weakened components can cause filter, pump or valve attachments to separate and could 

cause serious bodily injury or property damage.

High voltage can cause serious or fatal injury. Always install a suitable GFCI at the power source of this 

unit as an added safety precaution. Article 681-31 of the NEC requires that a GFCI be used if this pump 

is used with a storable pool.

Never work on the pump while it is running or power is still connected. 

High voltage can cause 

serious or fatal injury. A suitable ground fault interrupter should always be installed at the power supply 

source of this unit. Be sure to ground the motor before connecting to electrical AC power supply. Failure 

to ground the motor can cause serious or fatal electrical shock hazard. 

DO NOT 

ground to a gas supply 

pipe line.

FOR CORD AND PLUG CONNECTED UNITS

Connect only to a ground type receptacle protected 

by a Ground Fault Circuit Interrupter (GFCI). Contact a qualified electrician if you cannot verify that the 

receptacle is protected by GFCI. Do Not Bury Cord. Locate cord to minimize abuse from lawn mowers, 

hedge  trimmers,  and  other  equipment.  To  reduce  the  risk  of  electrical  shock,  replace  damaged  cord 

immediately. To  reduce  the  risk  of  electrical  shock,  Do  Not  Use  an  extension  cord  to  connect  unit  to 

electrical supply; provide a properly located outlet.

3

Содержание 75131

Страница 1: ...ING INSPECTION MAINTENANCE AND CLEANING PROCEDURES WRITE THE PRODUCT S SERIAL NUMBER ON THE BACK OF THE MANUAL NEAR THE ASSEMBLY DIAGRAM OR MONTH AND YEAR OF PURCHASE IF PRODUCT HAS NO NUMBER OWNER S MANUAL AND SAFETY INSTRUCTIONS ITEM 75131 FOR QUESTIONS PLEASE CALL OUR CUSTOMER SUPPORT 909 628 0880 MON FRI 9AM TO 3PM PST ...

Страница 2: ...l Electrical Code and all applicable local codes and ordinances Improper installation may create an electrical hazard which could result in death or serious injury to pool users installers or others due to electrical shock and may also cause damage to property To reduce the risk of injury do not permit children to use or operate this pump and sand filter DO NOT store chemicals around your pool Che...

Страница 3: ... gravity drainage system with ASME ANSI cover s one or more unblock able outlets or B A multiple main drain system without isolation capability with suction outlet covers that meet ASME ANSI A112 19 8 Suction Fittings for Use in Swimming Pools Wading Pools Spas and Hot Tubs and either I A safety vacuum release system SVRS meeting ASME ANSI A112 19 17 Manufactured Safety Vacuum Release Systems SVRS...

Страница 4: ...he valve to separate which could cause serious personal injury and or property damage Always turn pump off before changing valve positions Changing valve positions while the pump is running can damage the control valve which may cause serious injury or property damage Chemical fumes and or spills can cause serious corrosion to the filter and pump structural components Structurally weakened compone...

Страница 5: ...res 4 way valve Filter Backwash Rinse Winter Pump 110V 1 2HP pump 50GPM Flow Rate Self priming ultra quiet pump Weather and heat resistant Capacitor start feature 4 BACKWASH AND RINSING PORT Waste port for backwashing and rinsing MULTIPORT VALVE Controls flow in and around the tank STAND PIPE ASSEMBLY Allows filtered water to exit the tank LATERAL ASSEMBLY Allows water to enter the stand pipe keep...

Страница 6: ...l check of the laterals Look for broken or loose laterals Replace if necessary The laterals of side mount valve sand filter are all installed 3 Match the Raised Point of the laterals to Folding Umbrella lateral holder insert the laterals and turn 90º clockwise Listen for a sound to confirm the lateral is in place 4 Make sure the air release hose is running along side the body of the lateral holder...

Страница 7: ... Multiport Valve are Flange clamp screws and O Ring 1 Screw the barrel unions onto the threaded ports on the Multiport Valve 2 When rotating the Multiport Valve into position on a Top Mount Filter leave some leeway for better alignment of plumbing 3 Once the Multiport Valve is in position and the plumbing is aligned apply the thread tape to the barrel union thread 4 Using a roll of Teflon tape wra...

Страница 8: ...the flow of water will start diminishing When the pressure gauge reading is 8 10 PSI higher than the initial Start up pressure it is time to backwash clean the filter CAUTION All suction and discharge valves must be open when starting the pump Failure to do so could cause severe personal injury and or property damage NOTE If a pump is installed switch the pump on and off instead of closing and ope...

Страница 9: ...4 Depress and turn Handle to the BACKWASH position In the BACKWASH position the water flow is automatically reversed through the filter so that it is directed to the bottom of the filter vessel up through the sand flushing the previously trapped dirt and debris out the waste line 5 Switch on the Pump Backwash water will flow out through drain pipe 6 When the backwash water in the sight glass appea...

Страница 10: ...ESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIEDAND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO Record Product s Serial Number Here Note If product has no serial num...