1500

 

USER’S

 

MANUAL

 

UNINTERRUPTIBLE

 

POWER

 

SUPPLY

 

(UPS)

 

 

IMPORTANT

 

SAFETY

 

INSTRUCTIONS:

  

(SAVE

 

THESE

 

INSTRUCTIONS)

 

This

 

manual

 

contains

 

important

 

safety

 

instructions.

 

Please

 

read

 

and

 

follow

 

ALL

 

instructions

 

carefully

 

during

 

the

 

installation

 

and

 

operation

 

of

 

the

 

UPS.

 

Read

 

this

 

manual

 

thoroughly

 

before

 

attempting

 

to

 

unpack,

 

install,

 

or

 

operate.

 

CAUTION!

 

To

 

prevent

 

the

 

risk

 

of

 

fire

 

or

 

electric

 

shock,

 

install

 

in

 

a

 

temperature

 

and

 

humidity

 

controlled

 

indoor

 

area,

 

free

 

of

 

conductive

 

contaminants.

 

(Please

 

see

 

specifications

 

for

 

acceptable

 

temperature

 

and

 

humidity

 

range).

 

CAUTION!

 

To

 

reduce

 

the

 

risk

 

of

 

electric

 

shock,

 

do

 

not

 

remove

 

the

 

UPS

 

cover.

 

Qualified

 

Service

 

Personnel

 

must

 

perform

 

ALL

 

repairs

 

and

 

maintenance.

 

No

 

user

 

serviceable

 

parts

 

inside.

 

CAUTION!

 

Hazardous

 

live

 

parts

 

inside

 

can

 

be

 

energized

 

by

 

the

 

battery

 

even

 

when

 

the

 

AC

 

input

 

power

 

is

 

disconnected.

 

CAUTION!

 

UPS

 

must

 

be

 

connected

 

to

 

an

 

AC

 

power

 

outlet

 

with

 

fuse

 

or

 

circuit

 

breaker

 

protection.

 

Do

 

not

 

plug

 

into

 

an

 

AC

 

wall

 

outlet

 

that

 

is

 

not

 

grounded.

 

If

 

you

 

need

 

to

 

de

energize

 

this

 

equipment,

 

turn

 

off

 

and

 

unplug

 

the

 

UPS.

 

DO

 

NOT

 

USE

 

FOR

 

MEDICAL

 

OR

 

LIFE

 

SUPPORT

 

EQUIPMENT!

 

Xtreme

 

Power

 

does

 

not

 

sell

 

products

 

for

 

life

 

support

 

or

 

medical

 

applications.

 

DO

 

NOT

 

use

 

these

 

UPS

 

in

 

any

 

circumstances

 

that

 

would

 

affect

 

operation

 

or

 

safety

 

of

 

any

 

life

 

support

 

equipment

 

or

 

with

 

any

 

medical

 

applications

 

or

 

patient

 

care.

 

NOTICE!

 

Not

 

for

 

use

 

in

 

a

 

computer

 

room

 

as

 

defined

 

in

 

the

 

Standard

 

for

 

Protection

 

of

 

Electronics

 

Computer/Data

 

Processing

 

Equipment.

 

NOTICE!

 

An

 

acceptable

 

outlet

 

(based

 

upon

 

UPS

 

Specifications)

 

shall

 

be

 

installed

 

near

 

the

 

equipment

 

and

 

shall

 

be

 

easily

 

accessible.

 

 

[4]

 

Содержание XVT?1200

Страница 1: ...Xtreme Value Tower Series XVT User s Installation Manual Xtreme Power Conversion Corporation ...

Страница 2: ...TION 5 DETERMINING THE POWER REQUIREMENTS OF YOUR EQUIPMENT 7 HARDWARE INSTALLATION GUIDE 7 QUICKSTART SOFTWARE INSTALLATION GUIDE 9 REPLACING THE BATTERY 14 DEFINITIONS FOR LED INDICATORS 15 ALARMS 15 TROUBLESHOOTING 16 SPECIFICATIONS 17 SHIPPING LIST OBTAINING SERVICE 19 18 XTREME POWER CONVERSION XPC CORPORATION LIMITED WARRANTY 20 2 ...

Страница 3: ...its for a Class B Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications There is no guarantee th...

Страница 4: ...tenance No user serviceable parts inside CAUTION Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected CAUTION UPS must be connected to an AC power outlet with fuse or circuit breaker protection Do not plug into an AC wall outlet that is not grounded If you need to de energize this equipment turn off and unplug the UPS DO NOT USE FOR MEDICAL OR LI...

Страница 5: ... Interactive Automatic Voltage Regulation AVR UPS technology Under normal AC power operation the input power flows through the AVR circuit regulating the incoming AC power to the output of the UPS and the load connected If the input power disappears the Inverter circuit is switched on to provide output from the batteries contained within the UPS 5 ...

Страница 6: ...ing a power failure Power Switch Can be used as a master on off switch for equipment connected to the battery powered outlets Power On Indicator This LED is illuminated when the utility condition is normal and the UPS outlets are providing power free of surges and spikes Circuit Breaker The circuit breaker that provides overload and fault protection USB Port protocol that provides communication be...

Страница 7: ...actors can affect the amount of power that your computer system will require The total load that you will be placing on the battery powered outlets should not exceed 85 of the UPS capacity HARDWARE INSTALLATION GUIDE 1 Your new UPS may be used immediately upon receipt however charging the battery for at least 4 hours is recommended to ensure that the batteries maximum charge capacity is achieved C...

Страница 8: ...he UPS on 6 Your UPS is equipped with an auto charge feature When the UPS is plugged into an AC wall outlet and there is acceptable AC voltage present the battery will automatically recharge Charging is controlled by firmware to rapidly charge units to 15VDC 600 800VA units and 29VDC 1200 1500VA units After this threshold is met the XVT places a float charge to maintain battery energy and the char...

Страница 9: ...ide the box 2 Insert one end of the USB Cable into the UPS and the other into a USB port on your computer 3 Insert the CD into your computers CD drive 4 When the software interface requests a serial number locate and input the serial number from the CD software jacket 5 Follow the software setup prompts 6 Quickstart Software Installation Guide 9 ...

Страница 10: ...VT 1500 USER S MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS Input user name company name and serial number into the software interface Note the serial number is on the CD software jacket Choose installation location and click Next 10 ...

Страница 11: ...XVT 600 XVT 800 XVT 1200 XVT 1500 USER S MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS Choose software language and click Next Software will install automatically 11 ...

Страница 12: ... XVT 1200 XVT 1500 USER S MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS Choose Will you run Powermanager II right now and click Finish After the UPS switches on please choose the System Setting tab from the drop down box 12 ...

Страница 13: ...XVT 600 XVT 800 XVT 1200 XVT 1500 USER S MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS Click Local UPS and choose USB click OK The UPS is now connected and in normal operation 13 ...

Страница 14: ...tem voltage is only 12VDC and 24VDC the battery can present a high risk of short circuit current and electrical shock The short circuit current capability of the battery is sufficient to burn wire or tools very rapidly producing molten metal Observe these precautions when replacing the battery 1 Remove all watches rings or other metal objects 2 Only use tools with insulated handles 3 Do not lay to...

Страница 15: ... Power OFF OFF FLASH On Battery ON Charge ON Overheat Low Battery Overload Protection Short Circuit Note means any situation ALARMS Alarm Indication Unit Status Buzzer every 5 sec DC start Buzzer every 1 sec Self test 2 buzzer every 1 sec Low battery 4 beep every 2 4 sec Overload 3 buzzer every 1 sec Overheat Input is off long beep power off after 5 sec Short circuit 15 ...

Страница 16: ...least 4 hours The battery is defective Contact Xtreme Power Conversion about replacement of batteries The UPS will not turn on The on off switch is designed to prevent damage by rapidly turning it off and on Turn the UPS off Wait 10 sec then turn the UPS on The UPS is not plugged into an AC wall outlet Connect the UPS to an 110 120V 60Hz AC wall outlet The battery is defective Contact Xtreme Power...

Страница 17: ...l load half load 3 min full load 6 min 50 load Charge Current 1 5A Max PHYSICAL Dimensions W x D x H inches W x D x H inches W x D x H inches W x D x H inches Product Dimensions 3 7 x 14 6 x 6 2 3 7 x 14 6 x 6 2 4 9 x 16 9 x 8 7 4 9 x 16 9 x 8 7 Shipping Dimensions 6 1 x 16 2 x 10 2 6 1 x 16 2 x 10 2 7 5 x 18 9 x 12 8 7 5 x 18 9 x 12 8 Product Weight 15 3 lbs 16 8 lbs 27 6 lbs 31 3 lbs Shipping We...

Страница 18: ...Mode Green LED on Orange LED on Red LED off no beep Charging Battery Orange LED on Battery Mode Green LED and Orange LED off Red LED flash buzzer slow beep Battery Low Green LED and Orange LED off Red LED on buzzer fast beep SHIPPING LIST 1 1 UPS 2 1 User s and Installation Manual 3 1 Intelligent monitoring software 4 1 USB computer port cable 18 ...

Страница 19: ...nician will ask you for the above information and if possible help solve your problem over the phone In the event that the unit requires factory service the technician will issue you a Return Material Authorization number RMA If you are returning the UPS to Xtreme Power for service please follow these procedures 1 Pack the UPS in its original packaging If the original packaging is no longer availa...

Страница 20: ... a the equipment is repaired or modified by anyone other than XPC Corporation or a XPC Corporation approved third party b the equipment is damaged by the customer is improperly used or stored is subjected to an adverse operating environment or is operated outside the limits of its electrical specifications or c the equipment has been used or stored in a manner contrary to the equipment s operating...

Страница 21: ...XVT 600 XVT 800 XVT 1200 XVT 1500 USER S MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS 21 ...